Quick answer

A fireplace insert chimney pipe is the liner that carries exhaust from the insert's flue collar up through the existing chimney. The Florida Building Code requires a masonry chimney to be lined with material suited to the appliance, and a UL 1777 listed liner is one route. The insert maker's manual decides which liner fits.

What the pipe behind an insert is

ABCDEF
  1. Chimney cap
  2. Top plate
  3. Stainless liner
  4. Existing chimney
  5. Appliance connector
  6. Insert
The parts this page names, on a simplified drawing of a fireplace insert and its liner inside a masonry chimney. Highlighted: the insert.

A fireplace insert is a heating appliance that slides into an existing firebox. The U.S. Environmental Protection Agency describes inserts as working much like freestanding wood stoves but designed to be installed within the firebox of an existing masonry or metal fireplace. Because the insert closes off the old opening, its exhaust has to go somewhere, and that is the pipe.

The pipe is usually a metal liner. It connects to the flue collar on top of the insert and runs up the chimney, so the exhaust travels in a sealed path of its own instead of drifting through the wide old flue.

What the Florida code says about lining

Section R1003.11 of the Florida Building Code, Residential, says masonry chimneys shall be lined, and that the lining material shall be appropriate for the type of appliance connected, in accordance with the appliance listing and the manufacturer's instructions. That sentence puts the insert's manual at the center of the decision.

Section R1003.11.1 lists the routes for residential-type appliances. They are clay flue lining that meets ASTM C315, listed and labeled lining systems under UL 1777, factory-built chimneys listed for installation within masonry chimneys, and other approved materials that resist corrosion, erosion, softening or cracking from flue gases and condensate at temperatures up to 1,800 degrees Fahrenheit.

A label on the wall

When a flue is relined with a material that is not one of the routes above, section R1003.11.6 requires a permanent label on a wall or ceiling near where the connector enters the chimney. The label says the flue is for use only with a named type of appliance that burns a named fuel, and that other appliances must not be connected.

That label is for the next owner and the next technician. If you have an insert and no label, ask what is in the flue and whether the paperwork shows it.

Reading the liner kit and the manual

ABC
  1. Brick wall of the chimney
  2. Liner
  3. Flue passage
A chimney seen from above, cut across the flue, simplified and not to scale, with the liner picked out in colour.

A liner kit is only right if it matches the insert. These are the questions a manual and a kit have to answer together.

  • What size is the insert's flue collar, and what liner size does the maker call for?
  • Does the manual call for a liner the full height of the chimney, or does it allow another connection?
  • Is the liner listed to UL 1777, and does it suit the fuel the insert burns?
  • What parts finish the top, such as a top plate and a cap?
  • How will the liner be supported and sealed at the bottom?
  • Where does the label go?

Why the old flue is not simply left as it is

An open fireplace and a closed insert are sized on different bases. Section R1003.15 of the Florida code sizes the flue for a masonry fireplace to the opening, which is a very different basis from a closed insert. The insert's manual says what liner it needs, and that is why the old flue is not simply reused.

The EPA adds that a masonry chimney's flue liner should be checked as installed correctly when an insert is fitted. A cracked clay liner, a missing section or a blocked flue can all go unseen behind an insert.

How an insert chimney is cleaned

The U.S. Fire Administration advises having heating equipment and chimneys cleaned and inspected each year by a professional. For an insert that means the liner as well as the insert, and the work is done from the top of the chimney or by pulling the insert forward so the connector can be reached.

Section R1003.9.2 of the Florida code requires that when a spark arrestor is installed on a masonry chimney, it is located with access for cleaning and that the screen or the cap is removable so the flue can be cleaned. A cap that is fixed in place makes a liner harder to clean. Our chimney sweep page explains what a cleaning visit includes.

What installing a liner for an insert involves

A professional installation usually follows a pattern. The crew checks the existing chimney, sizes the liner, lowers it from the top and connects it to the collar, then fits the top plate and cap and records the work. That sequence depends on the manual, the chimney height and the condition of the old flue.

This is not a job for a ladder on a Florida roof or for a kit from a store shelf. Working at the top of a chimney is a fall risk, and a liner connected wrongly leaks exhaust into the wall. Read chimney liner installation for how it goes.

An insert with no record of its liner

If you are fitting an insert or have one with no record of its liner, we can look at it. See fireplace insert installation. Sarasota Chimney Repair is locally owned and family owned and operated, and our experienced crew is Proudly American. Ask for a free on-site inspection and a written estimate.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

What is an insert fireplace?

An insert is a heating appliance built to sit inside the firebox of an existing fireplace. The EPA says inserts work much like freestanding wood stoves. The insert replaces the open fire, and a liner carries its exhaust up the chimney.

Do i need a chimney liner for fireplace insert?

Under the Florida code a masonry chimney must be lined, and the lining must suit the appliance under its listing and the maker's instructions. The manual for your model says which liner it needs, so read it and have the flue checked.

What is a fireplace chimney?

A fireplace chimney is the vertical structure that carries smoke and gases from the fireplace out above the roof. It may be masonry or a factory-built metal system. The Florida code requires masonry chimneys to be lined and factory-built chimneys to be listed.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Describe the change

    Tell us where water, soot or damage appeared and when you first noticed it.

  2. Review the condition

    We look at the relevant system and separate the symptom from the component requiring attention.

  3. Agree on the work

    Choose the proposed service after the materials, access and price have been explained.

  4. Understand the result

    We review the completed work and any operating or maintenance questions that remain.