How to Correctly Flash Around a Chimney

Base, step, counter and cap flashing, the cricket, and what the Florida Building Code asks of each.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Flashing around a chimney in Florida is two layers of metal that overlap: base flashing set against the roof and counterflashing set into the masonry and lapped over it. The 2023 Florida Building Code requires flashing wherever a wall meets a roof, so the junction should never rely on caulk alone.

Why a chimney needs flashing at all

A chimney interrupts the roof. Water that runs down the slope has to be steered around the masonry and over the roofing, not into the gap between them. The 2023 Florida Building Code, Residential, section R903.2.1 requires flashing at wall and roof intersections, at any change of roof slope or direction and around roof openings, and says metal flashing must be corrosion resistant.

The Brick Industry Association's residential chimney note puts the same idea in building terms: all exterior spaces between the chimney and adjacent components should be sealed, usually by flashing and caulking. Caulking supports flashing. It is not a replacement for it.

The parts of chimney flashing

Words differ between roofers and masons, so it helps to name each piece:

  • Base flashing: metal installed first on the chimney faces that run across the roof, with tabs at each corner. The brick note says it should extend at least 4 inches up the chimney face and along the roof.
  • Step flashing: individual pieces woven into the shingle courses along the sides of the chimney, stepping up the slope, where the code allows step flashing or continuous L flashing on sidewalls.
  • Counterflashing, also called cap flashing: metal set into a mortar joint of the chimney and turned down over the base flashing. The brick note puts the insertion at three quarters to one inch into the joint, lapping the base flashing by at least 3 inches.
  • Cricket: a small roof-shaped saddle on the uphill side of a wide chimney that sheds water around it.

What the code says about the cricket

ABCDEF
  1. Chimney
  2. Counter flashing
  3. Step flashing
  4. Apron flashing
  5. Cricket
  6. Roofing
A chimney where it meets a sloped roof, seen from the side, simplified and not to scale, with the chimney picked out in colour.

The Florida Building Code requires a cricket or saddle on the ridge side of any chimney more than 30 inches wide, measured parallel to the ridge (R903.2.2). The chapter 10 table gives its height by roof pitch (R1003.20). A cricket covering must be sheet metal or the same material as the roof, and where it meets the chimney it is flashed and counterflashed like any other junction.

A wide chimney without a cricket lets water pile up behind it. That is a common reason a flashing that looks sound still leaks.

Order of installation

The sequence matters, because the layers have to shed water the way shingles do, overlapping downhill:

  • Roof covering and underlayment are installed or lifted to the chimney base.
  • Base flashing goes on the lower face first, then the sides with step flashing, then the upper face with the cricket if there is one.
  • Each upper piece laps over the lower one. The brick note calls for at least 2 inches where flashing is installed in sections.
  • A groove is cut into the mortar joint, counterflashing is set in and mortared or sealed solid, and turned down over the base flashing.
  • All joints and the unexposed side of any bends are sealed.

Tile and metal roofs are different

On a clay or concrete tile roof, the code's section on flashing where tile meets vertical surfaces points installers to the Florida High Wind tile installation manual it names (R905.3.8), so a tile roof junction is not copied from a shingle detail. Asphalt shingle roofs have their own provisions, including a minimum 4 inch by 4 inch continuous L flashing option on sidewalls (R905.2.8.1).

Metal roof flashing follows the roof maker's published details. The practical advice is to confirm which roof type you have and ask for flashing that follows that roof's instructions.

Signs your chimney flashing has failed

Rust streaks or lifted metal at the roof edge of the stack, gaps filled with old caulk, a stained ceiling that darkens after rain and damp near the chimney breast all point toward the junction. The stain's position does not prove the entry point, so a technician should trace the water before replacing metal.

Do not climb up to smear sealant on a failing junction. A roof edge is a fall hazard, and a tube of roof cement over rusted metal only hides the problem for a season.

Getting flashing done right

A proper repair cuts counterflashing into the brickwork and rebuilds the base layer in the roof's own system. Read about chimney flashing repair, then ask for a free inspection and a free written estimate. Experienced hands, a local, family-owned business and Proudly American work behind it.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

How is flashing installed around a chimney?

Base flashing goes against the roof first, step flashing runs along the sides, and counterflashing is set into a groove in the mortar and turned down over it. Every upper piece laps over the lower one so water sheds downhill. The joints are then sealed.

Does chimney flashing go under or over the shingles?

Base flashing and step flashing weave in with the shingles, so the shingle above overlaps the metal. The counterflashing then laps over the base flashing from the chimney side. The overlap always runs downhill. On a tile or metal roof the maker's instructions set the detail.

Is caulk enough to seal a chimney roof junction?

No. The Brick Industry Association describes caulking as supporting flashing, not replacing it. Caulk shrinks and cracks in sun and rain, so a junction that depends on it fails sooner than one built with overlapped metal. Ask any proposal to name the metal it will install, not only the sealant.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Identify the concern

    Leaks near the roof and chimney junction, or another change you have noticed.

  2. Review the recommendation

    Understand the proposed task, relevant materials and access.

  3. Authorize the work

    Agree on the price and the scope before the paid job begins.

  4. Keep the work record

    Retain the component details and any remaining recommendations.