Putting a Gas Fireplace Insert Into an Existing Chimney

What the chimney has to be, and what has to be done to it, before a gas insert is installed in an existing fireplace.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

An existing masonry chimney can take a gas fireplace insert, but the chimney comes first. The maker requires the fireplace and the whole chimney to be inspected and cleaned, damaged parts repaired, the damper handled and a correctly sized liner run to a proper cap.

Does a gas insert need a chimney?

An insert replaces the open fire, not the chimney. A direct vent insert uses the old chimney as a pathway for its own sealed liner. The Mendota FV44i manual says the insert must vent vertically to the outside through approved flexible ducting, that horizontal runs are not allowed, and that it must never be attached to a chimney serving a separate solid fuel-burning fireplace.

So a fireplace with a chimney is what the insert is designed for. A house with no chimney at all is a different project, and one with a chimney in poor condition is a repair project first.

The chimney has to pass inspection first

Mendota's installation plan must include inspection and cleaning of the fireplace cavity and the entire chimney. The chimney top, especially masonry and wood-framed tops, must be inspected, and the top surface repaired or replaced if necessary. Unlined flues are called the most vulnerable to mortar corrosion, and they must be inspected and repaired before the flex liner is dropped.

The manual also says that if the firebox is badly deteriorated or damaged, installation does not go ahead until the damaged structure is reviewed and local building officials approve the repair. It warns that skipping inspection and cleaning can cause odor, water penetration and damage to the unit's electronics.

Liners: what goes down the chimney

The insert connects to flexible liners that run all the way up. Mendota describes a co-linear system with a 4 inch exhaust liner and a 3 inch air intake liner, or a coaxial system of a 4 inch exhaust flex inside a 6 inch air flex when the chimney is too tight for two separate liners.

It says to run both liners to the vent cap whenever the flue size allows, and to avoid cutting the air liner short. Seals must be permanent and airtight with no silicone at the joints, and both screws and hose clamps are used at all four connection points. The liner is chosen to the insert and the flue, not by guess.

Damper, cap and clearance at the top

ABC
  1. Spark and animal screen
  2. Flue tile
  3. Top courses of brick
The top of a brick chimney, close up, simplified and not to scale, with the flue tile picked out in colour.

The existing damper does not just stay as it is. The Mendota manual says the fireplace flue damper can be fully blocked open or removed for the installation, and that chimney cleanouts must fit properly.

At the top, the insert's vent cap is a full-size cap, not a low-profile one, because low-profile caps are vulnerable to exhaust recirculation and ghosting flames. The manual asks for at least 3 inches of clearance from the top of the vent cap to the existing chimney cap, and 6 inches for caps wider than 16 inches. If a wood-burning flue sits next to the gas vent cap, it asks for a divider or a taller wood flue liner.

Gas, power and the barrier screen

Beyond the chimney, the insert needs a gas supply of the type on its rating plate, a 120 volt power connection and its barrier screen. The Superior manual says a qualified service person must connect a fireplace to the gas supply, and it calls for leak detection fluid on every joint and never an open flame to check for leaks. Check carbon monoxide alarms outside the sleeping areas before the first fire.

The Florida code side

Chapter 24 of the 2023 Florida Building Code, Residential, requires appliances to be listed and labeled for the application (G2404.3) and installed as the terms of their approval require, with the maker's installation instructions on the job site at inspection (G2408.1). The Mendota manual adds that the installer must obtain required building permits and inspection approvals from the local building department.

Doing it with us

ABCD
  1. Chimney cap
  2. Stainless liner
  3. Existing chimney
  4. Insert
Not drawn to scale. The numbered parts are named below, with the insert highlighted.

Our gas fireplace insert installation starts with a look at the chimney, because that decides the liner, the cap and whether a repair comes first. We are a local, family-owned crew with hands-on experience, and the company is Proudly American.

Book a free inspection and we will write up the chimney work and the insert work together.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Do you need a chimney for a gas fireplace insert?

For the Mendota direct vent insert we read, yes: it vents vertically through flexible liners inside an existing chimney and permits no horizontal runs. Other inserts may use different venting, so the model's manual decides. An existing chimney must also be inspected and cleaned before any liner goes in.

How do I install a gas fireplace in an existing chimney?

The sequence is inspection and cleaning, repair of anything damaged, damper blocked open or removed, then a flexible liner pair to the vent cap, then the gas, power and barrier screen. Each step follows the model's manual, and a qualified person makes the gas connection.

Can an electric insert go into an existing gas fireplace?

Often yes, but the gas line must first be shut off and closed off properly by a qualified person. An electric insert needs power and no vent, so the chimney is not part of the job. The opening still has to meet that unit's size and clearance rules.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Describe the change

    Tell us where water, soot or damage appeared and when you first noticed it.

  2. Review the condition

    We look at the relevant system and separate the symptom from the component requiring attention.

  3. Agree on the work

    Choose the proposed service after the materials, access and price have been explained.

  4. Understand the result

    We review the completed work and any operating or maintenance questions that remain.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473