Skip to content

Proudly American · Family-Owned & Operated

Call (941) 337-7473

Call (941) 337-7473 Book a Free Inspection

Family owned and operated

Should a Gas Fireplace Pilot Light Always Stay On?

It depends on the ignition system your fireplace was built with.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Standing pilots are built to burn all the time, so a gas fireplace pilot light should stay on only if the unit has one. Units with electronic ignition light a pilot only when the fireplace is called on. Check your manual for the type, and turn a standing pilot off only by the steps on the unit's label.

Two kinds of pilot

Whether the pilot should be on depends on how your fireplace lights its burner. Superior's manual, which covers both, describes a continuous or standing pilot, whose flame stays on after the main flame goes off, and intermittent pilot ignition, where the pilot is lit before the main flame turns on and shut off again afterward. The first is a small flame you can see whenever the burner is off. The second shows no flame until you ask for heat.

  • A small steady flame all day with the burner off: a standing pilot doing its job.
  • No flame until the remote or switch is used, then a spark and a pilot: electronic ignition, and a pilot that stays out is normal.
  • A pilot flame with a yellow tip: Superior says that can mean dust and dirt in the pilot assembly.
  • A pilot that goes out whenever you let go of the knob: a sensor, connection or gas supply fault.
  • A pilot that will not light at all: gas off, a knob not fully pressed in, or no spark.

Why a standing pilot burns all the time

ABCDE
  1. Burner
  2. Pilot assembly
  3. Flame sensor
  4. Gas valve
  5. Gas supply line
Simplified drawing, not to scale. The pilot assembly is marked in colour.

The pilot has a second job beyond lighting the burner. On a standing-pilot millivolt system, the Desa and IHP guide explains, the pilot keeps the thermocouple hot to prove the flame, and keeps the thermopile hot to power the switch circuit. If the pilot is out, the burner cannot run, and the valve closes so no gas flows. That is why the pilot is designed to stay on while the unit is in service.

Should you turn it off for the summer?

Some owners turn a standing pilot off when they will not use the fireplace for months. The maker's manuals give a shut-off procedure for that, so it can be done, and the right steps are on your unit's label. The usual pattern in the manuals we read is to set any thermostat to the lowest setting, turn the knob clockwise to off, which on some units needs the knob pushed in slightly and never forced, and turn off the electrical power to the appliance, as one vent-free insert label lists.

The trade-off is that a pilot left off for a long time can collect dust before you relight it. Superior says additional cleaning may be needed for proper pilot operation based on use or lack of use. If it has been off for months, have the pilot and burner looked at before the first relight of the season.

Relighting a standing pilot

Follow your own label first, since controls differ. The pattern in the manuals is the same. One vent-free insert label says to turn the gas off and wait five minutes for any gas to clear, then smell for gas, including near the floor. If you smell gas, stop and follow the gas-smell instructions instead. If you do not, turn the knob to pilot and press it in, and light the pilot with the igniter or match the label names. Keep the knob pressed for the time the label gives after the pilot lights, which is about 30 seconds in the Desa guide and one minute on that insert label, then release it. The pilot should stay lit.

If it does not stay lit after several tries, turn the knob to off and call a service technician or the gas supplier, as the manual says. Use only your hand on the knob. If the knob will not push in or turn, do not use tools to force it.

Why the pilot goes out or will not light

The same short list comes up in every troubleshooting table. The gas is off at one of the several shutoffs a unit can have. The knob was not pressed in long enough or fully. The pilot flame does not heat the thermocouple, so it cools and the valve closes. The thermocouple connection is loose. The pilot hood or orifice is clogged. Gas pressure is low, or a propane tank is nearly empty. On an electronic unit, the batteries are dead. Each is a quick check for a technician and most are not safe for a homeowner to adjust.

Florida rules that sit behind the pilot

The 2023 Florida Building Code, Residential, section G2432.2, requires decorative gas appliances, with the exception of manually lighted natural gas decorative appliances, to have an igniter, direct ignition device or pilot flame plus a flame safeguard that shuts off fuel when the ignition means stops working. That safeguard is the reason a pilot that dies shuts the gas valve and does not keep feeding the burner. It is not something to bypass.

When to stop and call

If you smell gas at any point, leave the house and call the gas utility or 911 from outside, and do not use a switch or phone inside. Call us if the pilot will not stay lit after a few tries, if the knob will not move by hand, or if the pilot flame is yellow, tall or sooty. Our gas fireplace repair visit starts with the pilot, the sensor and the gas supply. We are a local, family-owned crew with experienced technicians, and we are Proudly American. Call (941) 337-7473 for a free on-site inspection and a free written estimate.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Should pilot light always be on gas fireplace?

Only if the fireplace has a standing pilot, which is made to burn all the time. A unit with electronic ignition lights a pilot only when you call for heat, so a dark pilot is normal there. Your manual or the label inside the control compartment says which type you have.

How to keep pilot light lit on gas fireplace?

Keep the pilot clean and positioned on its sensor, and keep the connections tight and gas supplied. Dust or soot in the pilot assembly, a loose thermocouple and low gas pressure are the causes maker manuals list. Those need a technician, so call if the pilot goes out again after one clean relight.

How to turn off pilot light on gas fireplace?

Use the shut-off steps printed on your unit's label. The usual pattern is to set a thermostat low and turn the control knob to off, pushing it in slightly if it will not turn. Never force it or use tools, and call a technician if the knob is stuck.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Describe the change

    Tell us where water, soot or damage appeared and when you first noticed it.

  2. Review the condition

    We look at the relevant system and separate the symptom from the component requiring attention.

  3. Agree on the work

    Choose the proposed service after the materials, access and price have been explained.

  4. Understand the result

    We review the completed work and any operating or maintenance questions that remain.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473