Family owned and operated
How to Fix a Gas Fireplace That Won't Light
The order to check things when a gas fireplace will not light or will not stay lit, and where your part ends.
- Licensed & insured
- Same-day service is available
- Locally run
Book Your Free Inspection
Takes about 30 seconds
Request received
Your appointment will be confirmed separately.
Quicker by phone? Call (941) 337-7473
Quick answer
Fixing a gas fireplace that will not light follows a check order: gas supply valve, power or batteries, then the pilot and its thermocouple. The Real Fyre troubleshooting table lists those causes. Simple checks are safe for you, but a gas smell, a stuck knob or a pilot that keeps going out means stop and call.
First, the safety rules that come before any fix
Every maker manual we read starts with the same gas warnings. Smell around the fireplace and near the floor before lighting, because some gas is heavier than air and settles there. If you smell gas, do not light anything, do not touch electrical switches or use a phone in the building, open a window, and call your gas supplier from outside or a neighbor's phone, or the fire department if you cannot reach them.
Use only your hand to push in or turn the control knob and never tools. If the knob will not push in or turn, the Real Fyre manual says not to try to repair it and to call a qualified service technician, because force or attempted repair may cause fire or explosion.
Step 1: The gas supply and the valve
The Real Fyre G45 troubleshooting table lists, among causes of a pilot that will not light, a gas supply that is off or a manual shutoff valve that is closed, and air in the gas line. After work on the gas line, or after months of not using the fireplace, the manual says it may take several minutes before the air is purged and the pilot lights.
Find the equipment shutoff valve for the fireplace and check that it is fully open. If the fireplace burns propane, an empty tank looks exactly like a dead fireplace. The Superior manual adds that on a new or long-idle appliance the first lighting of a season can take several attempts. Gas lines, tanks and regulators beyond that valve are not yours to touch.
Step 2: Power, batteries and switches
Many units depend on something electrical. The same table lists dead batteries and, for electronic spark, checking that the unit sparks when activated, with a loose igniter wire as a cause. Replace remote and receiver batteries, confirm the wall switch or remote is on and that any safety shutoff switch on the unit is on.
A unit with a battery-powered receiver may also have a three-position switch that must be in the right position before the remote works, as the 02-series instructions show. If it still will not respond, do not take apart wiring. That is a service call.
Step 3: The pilot, the knob sequence and the wait
For a hand-lit pilot, the manual's sequence has fixed steps. Push in the knob slightly and turn it to OFF. Wait five minutes for any gas to clear. Turn to PILOT, push the knob in firmly, hold a long match or lighter near the thermocouple and keep the knob held in for about 60 seconds after the pilot lights. If the pilot fails to light, repeat. If it still fails after several tries, turn the knob to OFF and contact a qualified service technician.
Do not poke at the pilot. The Superior manual warns never to use a wire, needle or similar object to clean a pilot because it can damage the pilot unit. The Real Fyre table lists a blocked pilot hood as a cause and calls for checking for debris or dirt, which is a technician's cleaning.
If the pilot lights but will not stay lit
- Gas logs
- Burner
- Pilot
- Flame sensor
- Gas valve
- Gas supply line
That points to a different list in the same table.
- The thermocouple nut is loose at the control valve; the manual says to tighten it, without over-tightening.
- The thermocouple is cracked or worn out and is replaced.
- The pilot hood is bent or not aimed so that the flame hits the thermocouple.
- The pilot line is bent or kinked where it connects to the valve.
- The valve will not hold and needs replacement.
- Excessive downdraft in the chimney, for which the manual points to a chimney cap, chimney height or chimney design.
If the burner lights and then shuts down
The manual lists insufficient or excessive gas pressure, log placement, a flue or damper dirty from soot, a fireplace too small for the unit, or the pilot flame lifting off the thermocouple. Other gas appliances on the same line can drop pressure to the logs, so pressure is checked with everything running.
None of that is a homeowner's check. Gas pressure, flues and dampers belong to a qualified technician or the gas company.
What a repair visit covers, and how to book one
A technician repeats this order with test equipment: valve, supply, ignition, pilot, thermocouple and burner, then the vent path. Our gas fireplace repair visit ends with a plain explanation of what failed and what it needs. Our technicians are experienced, and we are a local, family-owned company, Proudly American.
Ask for a free inspection and a written estimate. If the fireplace has a key valve rather than a knob, see how to light gas fireplace with key.
Sources
- Florida Building Code, Residential, 2023, chapter 24 Fuel Gas: Appliances installed per manufacturer instructions (G2408.1)
- US Fire Administration, carbon monoxide: Carbon monoxide alarms outside each sleeping area; keep vents clear
- EPA, what is carbon monoxide: Carbon monoxide symptoms; blocked flues
- Real Fyre G45 vented gas log burner installation and owner's manual (R.H. Peterson): Troubleshooting table for pilot will not light, will not stay lit, burner shutting down, will not turn on; manual pilot sequence with five minute wait and 60 second hold; do not use tools on the knob; air in the gas line
- Real Fyre automatic remote lighting safety pilot system owner's manual APK-11 (R.H. Peterson): Safety valve and pilot lighting sequence; pilot flame encircles the generator tip
- Superior DRT4036 and DRT4042 direct vent gas fireplace installation and operation instructions: Never use a wire or needle on the pilot; first lighting of a season may take several attempts; safety shutoff switch
- Family owned and operated
- Licensed & insured
- Same-day service is available
- Locally run
Plain Answers About Chimney Problems
- Can You Leave a Gas Fireplace On All Night?What two maker manuals say about sleeping with a gas fireplace running, and what to do at bedtime instead.Learn more
- How to Light a Gas Fireplace With a KeyThe lighting sequence for match-light logs with a key valve, and the safety steps that go with it.Learn more
- Does a Propane Fireplace Work When the Power Is Out?Which gas fireplace controls need no electricity, which need batteries, and what stays unsafe in an outage.Learn more
- Why Does My Gas Fireplace Smell So Bad?Some fireplace smells fade on their own. One kind means leave the house now.Learn more
Proudly American
A family-owned Sarasota company that explains the price before the work begins.
Questions Sarasota Homeowners Ask Us
How do I fix the pilot light on a gas fireplace?
Start by checking the gas valve and relighting by the manual's sequence: knob to OFF, wait five minutes, then PILOT, hold the knob in about 60 seconds. If the pilot will not stay lit, the cause is often a loose, cracked or worn thermocouple. Do not poke the pilot with a wire; have it serviced.
What should I do if my gas fireplace won't light?
Check for gas smell first and stop if you find any. Then confirm the gas valve is open, replace batteries and check switches, and try the manual's lighting sequence once or twice. If it still fails after several tries, turn the knob to OFF and call a qualified technician.
Why does my gas fireplace pilot keep going out?
The maker's table lists a loose or worn thermocouple, a pilot hood aimed away from it, a kinked pilot line, a valve that will not hold, or strong downdraft in the chimney. Each has a different repair, and the valve and gas parts need a qualified technician.
Book Within 72 Hours of Your Free Inspection and Save 10%
Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.
From Your First Call to the Finished Repair
-
Describe the change
Tell us where water, soot or damage appeared and when you first noticed it.
-
Review the condition
We look at the relevant system and separate the symptom from the component requiring attention.
-
Agree on the work
Choose the proposed service after the materials, access and price have been explained.
-
Understand the result
We review the completed work and any operating or maintenance questions that remain.
Ready When Your Chimney Is
Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.