Skip to content

Proudly American · Family-Owned & Operated

Call (941) 337-7473

Call (941) 337-7473 Book a Free Inspection

Family owned and operated

What Causes Draft Problems at an Indoor Fireplace

Air that moves through the firebox when it should not, and the leaks that explain it.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Interior fireplace draft issues come from air moving through the fireplace when it should not, or failing to move when it should. Common sources are a damper that does not seal, an ash dump or cleanout door that fits loosely, an air inlet left open, and a house pulling air down the flue. Each leaves a different sign.

Two things people call a draft

A draft at the fireplace can mean two opposite things. One is air moving through the firebox into the room while no fire burns, felt as a cold or damp stream, a smell or a whistle. The other is the flue failing to pull while a fire is lit. This page is about the first. For fire-time smoke, see our smoking fireplace guide.

Masonry fireplaces are built with deliberate openings. Brick Industry Association Technical Note 19A describes a damper, an optional ashpit and an optional outside air inlet, each of which has to close properly to keep a fireplace from leaking air when it is not in use.

Where the air is coming from

Match the sign you feel to the part most likely responsible. Each entry below ties to a source.

  • A cold or damp stream from the opening when no fire burns: a damper that does not seal. Technical Note 19A recommends tight-fitting dampers for an efficient fireplace, and says the damper is seated on a thin mortar bed to prevent gas and smoke leakage.
  • Air at floor level beside the hearth or from a small door below the firebox: an ash dump or cleanout door that does not close tightly. The Florida Building Code says cleanout doors must remain tightly closed except when in use (R1001.2.1), and the Brick Industry Association asks for a tight metal door.
  • A steady breeze that stops when a louver is closed: an outside air inlet left open. The Brick Industry Association calls for a screen-backed closeable louver, preferably operable from inside the house, and the code requires the outlet to be closable (R1006.5).
  • Air rushing down the flue when kitchen or bath fans run: a house short of make-up air. The code requires an exterior air supply for a fireplace unless the room is mechanically ventilated and kept neutral or positive in pressure (R1006.1).
  • A damper handle that moves but the plate does not: a damper that no longer works from the room. The code requires a damper that can be operated from the room containing the fireplace (R1001.7.1).

What the code and the maker say about air inlets

The Florida Building Code asks for the exterior air intake to be covered with a corrosion-resistant screen of 1/4 inch mesh, and bars it from being in a garage or basement (R1006.2). The Brick Industry Association adds that a garage air source is restricted in many codes to keep automobile exhaust out of the house.

An inlet that cannot be closed from inside is a draft you cannot stop. If the louver is stuck, rusted or blocked by landscaping, the fireplace leaks whether or not it is used. A technician can free or replace it.

What you can check without tools

Look at the damper with a flashlight. Move the handle and watch whether the plate closes fully. Check that the ash dump or cleanout door, if there is one, shuts squarely. Close any outside air louver. Then hold a strip of tissue near the opening on a windy day. If it still flutters with the damper closed, air is passing somewhere that needs a closer look.

A chimney pillow or flue blocker can keep air out, but it is not a repair, and it must come out before any fire. Our draft stopper guide explains how they work. Blocking a draft covers temporary measures.

Why it matters in a Florida house

A leak through a fireplace carries outdoor air into a house that is being cooled. The National Weather Service Tampa Bay office records for Sarasota-Bradenton show a dew point as high as 82 degrees Fahrenheit, reached on August 13, 2023, so summer air at the flue can be very wet. The Florida Building Code's exterior air and damper rules (R1006 and R1001.7.1) address how air moves through a fireplace.

When the draft is a sign of something bigger

ABCD
  1. Makeup air
  2. Fireplace
  3. Smoke and gases rising
  4. The house
The parts this page names, on a simplified drawing of how air moves through a house with a burning fireplace. Highlighted: the fireplace.

Soot or a sharp smoky smell when the fireplace is cold, a damper stuck open or shut, rust on the firebox floor and a draft that appears suddenly point to a worn damper, a leaking flue or a missing cap. The US Fire Administration advises a professional cleaning and inspection of fireplaces and chimneys every year. Air coming down the flue during a fire is another problem, covered in our back draft guide.

Next step for a Sarasota fireplace

Dampers, doors and air inlets are handled by an experienced crew that is local, family-owned and Proudly American, serving Sarasota, Venice and Bradenton. Fireplace repair starts by finding where the air moves, and a free inspection with a written estimate comes first.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Why do I feel cold air coming from my fireplace?

Air is moving through the firebox, most often past a damper that does not seal or through an open air inlet or ash door. Technical Note 19A recommends tight-fitting dampers, and the Florida Building Code requires cleanout doors to stay tightly closed and the outside air outlet to be closable (R1001.2.1 and R1006.5). Check the damper first.

What causes fireplace backdraft?

Backdraft is air moving down the flue instead of up. Exhaust fans, a closed damper and a chimney top that sits low can each cause it, and the Florida Building Code's exterior air rule (R1006.1) addresses the first. Our back draft guide walks through the checks in order.

What causes creosote in fireplace?

Creosote forms when wood burns slowly. Superior's outdoor fireplace manual and the US Stove manual both say slow burning makes tar and organic vapors that condense on the cooler flue lining. The EPA advises dry wood and hot fires, and a chimney that is cleaned and inspected each year keeps the buildup in check.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Identify the concern

    Damaged firebox surfaces, or another change you have noticed.

  2. Review the recommendation

    Understand the proposed task, relevant materials and access.

  3. Authorize the work

    Agree on the price and the scope before the paid job begins.

  4. Keep the work record

    Retain the component details and any remaining recommendations.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473