Quick answer
Chimney storm collar sealant is the non-hardening waterproof sealant that closes the gap where a storm collar meets a metal chimney pipe above the roof flashing. DuraVent's DuraPlus instructions put a ring of it under the collar and a bead along the pipe seam. Other makers' manuals govern their own pipe.
What a Storm Collar Is and Where It Sits
A storm collar is a metal band that wraps a factory-built chimney pipe just above the roof flashing. The flashing is the flat metal skirt nailed to the roof around the pipe. The collar rides on the pipe just above the flashing, and the maker's instructions have it slid down to the top of the flashing and sealed there.
DuraVent's DuraPlus product page lists roof flashing, storm collar and chimney cap as three separate parts of its all-fuel chimney, which is a fair picture of the layout. A masonry chimney meets the roof with base flashing and counterflashing, which section R905.2.8.1 of the Florida code covers, and that is a different job.
What the Sealant Under a Storm Collar Does
The collar is a clamp and the sealant is the seal. Tightening the band holds it in place, but the sealant fills the small gap between the band and the round pipe so water has no path through it. Where the sealant has split, shrunk or pulled away, the collar can look intact and still let water in.
A collar that has slid down, a loose band or a bent edge is a separate cause, covered below.
Which Sealant the Maker Names
For the DuraPlus system, the installation instructions name one material for these joints: a non-hardening waterproof sealant. It appears in the list of materials you may need, beside a caulking gun, and again in the steps for the flashing and the collar. The same manual names a high-temperature sealant for a different part of the system, an anchor plate, so the two are not interchangeable.
This page quotes the DuraPlus manual because it is the one we opened. Other makers publish their own instructions, and under the Florida residential code a factory-built chimney is installed and terminated according to the manufacturer's instructions. Which sealant belongs under your collar is therefore a question for the manual that matches your pipe, not for a general rule.
Chimney Storm Collar Installation: The Order of the Seals
On a DuraPlus chimney the manual puts the roof flashing in first, centered on the pipe, with its upper edge under the roofing and nails along the upper edge and the upper half of each side. The nail heads are then sealed with non-hardening waterproof sealant. The order matters because each layer sheds water onto the one below it.
- Flashing set in place, upper edge under the roofing, lower edge left unnailed.
- Nail heads in the flashing sealed with the non-hardening sealant.
- A ring of sealant applied around the pipe just above the flashing, where the collar will land.
- A bead of sealant run along the vertical seam of the pipe section, which the manual notes is exposed to the weather.
- The collar slid down the pipe to the top of the flashing, tightened and sealed against the ring of sealant.
- The chimney cap fitted on top. The manual says it can be removed later for cleaning.
Chimney Storm Collar Leaking: Where Water Gets Past It
- Chimney
- Counter flashing
- Apron flashing
- Roofing
When water shows up around a metal chimney after rain, the collar is one of several places to check, and it cannot be judged from inside the house. The signs below are things an inspection looks for from the roof, not things to test yourself.
A stain on the ceiling near the pipe does not say which of these is at fault. Flashing, collar and the roof around them can all be involved at once, and a repair aimed at the wrong one leaves the leak in place.
- Sealant that is cracked, split or pulled away from the pipe or the band.
- A collar that has slipped down and left a gap between its lower edge and the flashing.
- Sealed nail heads in the flashing that have opened.
- A pipe seam above the collar with no sealant along it.
- A band that is loose, bent or no longer round.
What Not to Do With a Storm Collar
The DuraPlus manual says not to put screws through the flashing into the chimney pipe. It also says that where the chimney passes through an enclosure cover, the collar is not to be pushed all the way down, so an air space remains for airflow between the pipe and the hole in the cover.
Those two lines show why a general-purpose fix goes wrong. A bead of caulk that closes an air space, or a screw that bridges the flashing and the pipe, breaks a rule the maker wrote into the installation. Do not climb onto the roof to add sealant yourself. A wet roof edge and a ladder are the usual way people get hurt on this job.
How the Florida Code Frames the Job
Section R1005.1 of the 2023 Florida Building Code, Residential, says factory-built chimneys shall be listed and labeled and installed and terminated in accordance with the manufacturer's instructions. A storm collar and its sealant are part of that termination, which is why the maker's manual is the reference.
The roof side has its own rule. Section R903.2.1 asks for flashing at wall and roof intersections and around roof openings, and says metal flashing shall be corrosion resistant. A collar is a second line behind flashing that has to be sound first.
Having Our Crew Seal the Collar
We are a local, family-owned crew, our technicians are experienced and the company is Proudly American. When we look at a metal chimney in Sarasota, Venice or Bradenton, we start from the maker's manual for that pipe and check the sealant, the collar and the flashing as one assembly.
A free inspection ends in a written estimate for chimney flashing repair, including the collar and its seal, when the roof junction needs work. If the stain is what worries you, how rain gets in around a chimney covers the other places to look.
Sources
- DuraVent DuraPlus Installation Instructions: Non-hardening waterproof sealant, flashing, storm collar steps, no screws through flashing, air space at enclosure cover
- DuraVent DuraPlus product page: Roof flashing, storm collar and chimney cap as parts of the system
- 2023 Florida Building Code, Residential, chapter 10 Chimneys and Fireplaces: R1005.1
- 2023 Florida Building Code, Residential, chapter 9 Roof Assemblies: R903.2.1
- Family owned and operated
- Licensed & insured
- Same-day service is available
- Locally run
Plain Answers About Chimney Problems
- Flash around a chimneyBase, step, counter and cap flashing, the cricket, and what the Florida Building Code asks of each.Learn more
- Stop back draftWhy smoke and air come back down a flue, and the checks that point to pressure, height, cap or blockage.Learn more
- Chimney Rain Pan and Where Water CollectsThe pan, the rain cap, the collar and the flashing each shed water in a different place. Here is how to tell which one is leaking.Learn more
- Why Does My Chimney Leak in Sarasota?Rain timing, top components and the roof junction help frame a leak assessment.Learn more
Proudly American
A family-owned Sarasota company that explains the price before the work begins.
Questions Sarasota Homeowners Ask Us
How to install chimney storm collar?
On a DuraPlus chimney, the collar goes on after the roof flashing is in place. Non-hardening waterproof sealant goes around the pipe above the flashing and along the pipe seam, then the collar slides down to the flashing and is tightened and sealed. Another maker's pipe may differ, so its own manual decides, and a professional should do the roof work.
Why is my chimney storm collar leaking?
The usual suspects are split or shrunken sealant, a collar that has slipped away from the flashing, opened nail-head seals in the flashing or an unsealed pipe seam above the collar. The stain inside does not show which one it is. A crew checks the whole junction from the roof.
Can you use caulk on a chimney storm collar?
Use the sealant the chimney maker names, not whatever tube is at hand. DuraVent's DuraPlus instructions name a non-hardening waterproof sealant for the collar and a different, high-temperature sealant elsewhere in the system. Check the manual for your pipe before anything is applied.
Book Within 72 Hours of Your Free Inspection and Save 10%
Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.
From Your First Call to the Finished Repair
-
Identify the concern
Leaks near the roof and chimney junction, or another change you have noticed.
-
Review the recommendation
Understand the proposed task, relevant materials and access.
-
Authorize the work
Agree on the price and the scope before the paid job begins.
-
Keep the work record
Retain the component details and any remaining recommendations.
Ready When Your Chimney Is
Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.