Electric Fireplace Problems and How They Are Solved

The faults a maker's troubleshooting table lists, and which fixes are safe to try yourself.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Electric fireplace problems fall into five groups: breakers, heater cutouts, flame faults, remotes and noise. The Dimplex service manuals pair each with a cause, from a loaded circuit to dust on the heater. Most first checks are safe once the unit is unplugged.

What an electric fireplace is made of

An electric fireplace has two systems that run separately. The flame effect uses a flicker motor, a flicker rod and LED lighting, and the heater uses a heating element, a blower and a thermostat. Dimplex says its flame and heater operate independently, which is why a unit can show flames without heat or heat without flames.

That split is the key to diagnosis. Tell a repair visit which half stopped, and the cause narrows at once.

Problems and the maker's explanation

These entries come from the Dimplex DWF3651 troubleshooting table and the Dimplex technical support page, since other makers differ in the details.

  • Breaker trips or lights dim when the unit starts: the unit is drawing close to the circuit rating. Dimplex says to try another outlet or a dedicated 15 amp circuit.
  • Heater turns off after a couple of minutes: dirt or dust in the heater assembly, or blocked intake louvers. Dimplex says to keep them clear, and a defective heater assembly is the second cause.
  • Flame frozen or shuddering: loose wiring or a defective flicker motor.
  • Flame dim or not visible: loose wiring, a defective LED light strip or a defective control board.
  • Heating element glowing red: small glowing sections are normal, but larger sections that trip the thermal cutout mean unplug the unit, stop using it and replace the heater assembly.
  • Odor when first used: normal for a brief period, as the heater burns off dust collected during manufacturing or use.
  • Power cord warm: slightly warm is normal, but a cord that is hot to the touch needs replacing.

Heat that cuts out and the overheat switch

An electric fireplace has an automatic overheat cutout. The Dimplex manual says the heater will not come back on until the cutout is reset, and that resetting means unplugging the unit and waiting 5 minutes before plugging it in again. It warns that if you need to reset it continuously, you should unplug the unit and call technical support.

The Dimplex support page names the usual trigger. The cutout trips if the ventilation slot at the bottom of the fireplace is covered or blocked, so the installation must not obstruct the air intake slots on the bottom front of the unit.

Flame, lights and the remote

The flame should be a constant, smooth flicker according to Dimplex. A shuttering or jumpy flame points to the flame motor, a flicker rod that has come off the motor shaft or a rubber grommet fitted backward. Light around the edge of a log set means the log set is out of position.

For a dead remote, Dimplex says to check the batteries, then follow the re-initialization steps in the owner's manual. A radio frequency disturbance from outside can also stop a remote from working. LED log sets have no replaceable bulbs inside, so a log set that stops glowing is replaced, after the wire connections are checked.

Problems to leave to a technician

The manual's own words are direct. Always use a qualified technician or service agency to repair the fireplace. Anything behind the front, such as a flicker motor, a relay board, a thermistor or a heater assembly, is a repair for someone who can test and replace parts. A unit that trips its cutout repeatedly, shows a burn smell or has a hot cord should stay unplugged.

The US Fire Administration's advice for heating equipment is worth following here too, since an electric fireplace is still a heater. Keep anything that can burn at least 3 feet from it.

Dust and damp air

Dimplex says its fireplaces can go in just about any indoor area as long as it is clean and dry. National Weather Service Tampa Bay records for Sarasota-Bradenton show a dew point as high as 82 degrees Fahrenheit. Keep the louvers and the cavity around the heater clear, as the service manual directs.

Next step for a Sarasota electric fireplace

ABCDEF
  1. Glass front
  2. Flame effect
  3. Heater and fan outlet
  4. Controls
  5. Power cord
  6. Wall outlet
Simplified drawing, not to scale. The flame effect is marked in colour.

Electric units get the same care as gas and wood from our local, family-owned and Proudly American company, and an experienced crew covers Sarasota, Venice and Bradenton. Electric fireplace repair handles heaters, flame motors, lighting and controls. Start with a free inspection and a written estimate.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Why does my electric fireplace heater keep shutting off?

The usual reason is the overheat cutout. Dimplex says the cutout trips if the ventilation slot at the bottom of the unit is blocked, or if the heater assembly is dirty, and that dust on the intake louvers should be cleared. Unplug the unit, wait 5 minutes and plug it back in, and call for service if it keeps tripping.

How do I reset an electric fireplace?

Unplug the unit and wait 5 minutes before plugging it back in. The Dimplex manual gives that as the way to reset the temperature cutoff switch after an overheat. If a remote has stopped working, its owner's manual has a separate re-initialization step. A unit that needs resetting again and again should stay unplugged until it is serviced.

Why is my electric fireplace flame not flickering?

Dimplex says the flame should be a constant, smooth flowing flicker, and lists three causes when it shutters or freezes. The flame motor may need replacing, the flicker rod may have come off the motor shaft, or the rubber grommet may have been fitted backward. The service manual also lists loose wiring as a cause.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Describe the change

    Tell us where water, soot or damage appeared and when you first noticed it.

  2. Review the condition

    We look at the relevant system and separate the symptom from the component requiring attention.

  3. Agree on the work

    Choose the proposed service after the materials, access and price have been explained.

  4. Understand the result

    We review the completed work and any operating or maintenance questions that remain.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473