Quick answer
Lighting a pellet stove manually is an emergency step, not a routine one. The Harman manual we read says to use the automatic igniter, allows hand lighting only on a cold stove with firestarter sold for pellet stoves, and says to repair the igniter soon. Never use gasoline or lighter fluid, and check your own stove's manual before you strike a match.
Start with the automatic igniter, which is how the stove is meant to light
The Harman P-Series owner's manual we read says pellet stoves should be lit with the automatic ignition system and calls it the safest and most reliable way to ignite the unit. Your stove may be another make, and its own manual always wins. We use Harman's here because it spells the steps out.
Its automatic start runs like this.
- Turn the Mode Selector to OFF and make sure the ash pan holds no fuel or other combustibles.
- Fill the hopper with pellets and scrape the burn pot clean if it needs it.
- After an empty hopper, turn the Feed Limit to TEST for one 60 second cycle so pellets reach the auger tube.
- Set the Feed Limit to 4, flip the Igniter Switch up to AUTO, set the temperature dial and turn the Mode Selector to Room Temperature or Constant Burn.
- Keep the view door closed. The manual says the auger motor will not run with it open.
- Once the stove ignites, expect it to burn for about 7 to 10 minutes before the igniter light turns off.
Emergency manual lighting, as one maker's manual describes it
Harman's manual treats hand lighting as emergency use only, for a stove whose igniter is not working, and says the igniter should be repaired or replaced as soon as practical. It carries a warning to use only firestarter sold for pellet stoves, such as wax coated wood chips, pellet starter gel or pellet igniter blocks. Any other type is prohibited, which leaves gasoline, lighter fluid and similar products out.
The manual sets conditions before you start.
- Cold start only. Never light by hand a stove that has run recently and is not at room temperature.
- If the automatic igniter was just tried, give the stove at least 30 minutes to cool to room temperature.
- The stove must be set to its igniter-disabled mode of operation.
The manual's four emergency steps
These are the maker's steps for its P-Series stoves, quoted in substance. Other models differ, so read yours first.
- Turn the Mode Selector to OFF.
- Fill the burn pot only halfway. Do not overfill it.
- Add firestarter to the pellets, following the firestarter maker's instructions.
- Light the gel with a match, close the door and turn the Mode Selector to Constant Burn. Operation begins when the fire reaches the proper temperature.
Why a pellet stove will not light
- Hopper lid
- Hopper
- Auger
- Burn pot
- Glass door
- Control board
A stove that will not light, or one that lights only by hand, usually has one of a few causes. Most trace back to the maker's own maintenance list.
- The igniter switch is left in the disabled position, so the igniter never gets power.
- Ash or carbon has built up around the igniter and in the burn pot. The manual's maintenance table lists cleaning the igniter monthly, with the stove off, cold and unplugged, by vacuuming loose ash from around it and inside the burn pot.
- The burn pot grate holes are packed. The manual says to clear them with the supplied allen wrench, with the fire out and the pot cold, without damaging the igniter element.
- The hopper ran empty and pellets never reached the burn pot. The TEST cycle above is the manual's answer.
- A door, ash pan or hopper lid is not sealing. The manual says the feed circuit needs enough draft in the firebox to work, so closed doors and sound gaskets matter.
- The igniter itself has failed. A Harman article on the Forge and Flame site lists a malfunctioning igniter among the causes, and says to check the manual for your model.
What the Harman status light is telling you
On the P-Series stove, the status light blinks a count when something stops the stove. These counts are Harman's for that line, and other makes use other codes.
- 2 blinks: an open feed circuit, typically from the pressure switch or hopper switch. It clears when the circuit is complete.
- 3 blinks: the exhaust sensing probe has failed, has a broken connection or has gone out of range too many times. It needs a manual reset, which means disconnecting the power cord for a few seconds.
- 5 blinks, igniter in Auto only: the stove failed to light within its 36 minute start cycle. Turn the Mode Selector to OFF, then back to a mode.
- 6 blinks: poor or incomplete combustion for more than 25 minutes. It can also be set when the stove runs out of pellets. Reset it the same way as 5 blinks.
Ash, outages and the rest of the fire-safety picture
Ash from a pellet stove can hold embers. The Harman article on Forge and Flame says never to put ash pan debris or unburned pellets back in the hopper, and to empty the pan into a metal container with a tight-fitting lid, kept away from anything combustible. Our guide on disposing of ashes safely covers the container and where to set it.
If the lights go out, the same article says the stove shuts down and the fire inside burns until it goes out, and that you should keep the doors closed so remaining smoke stays in the stove. Our guide to pellet stoves without power covers what happens next.
When to stop and call
Stop and call if the stove blinks 5 or 6 after you have cleaned the burn pot and igniter, if the igniter never glows, if smoke comes into the room or if you have been lighting it by hand more than once. The Harman manual says its troubleshooting guide can only be used by a qualified service technician, and a stove that needs hand lighting has a part that needs attention. Sarasota Chimney Repair is a local, family owned and operated crew with experienced technicians, and we are Proudly American. Book pellet stove service and ask for a free inspection and a free written estimate.
Sources
- Harman, P-Series Owner's Manual (P43-C, P61-C, P68-C), revision R5, January 2020, copy hosted by a stove retailer: automatic ignition steps, emergency manual ignition, firestarter warning, igniter cleaning, status light counts, troubleshooting for service technicians
- Forge and Flame, How to Light a Pellet Stove (Harman stoves): igniter malfunction as a cause, power outage shutdown, ash pan debris with embers
- Family owned and operated
- Licensed & insured
- Same-day service is available
- Locally run
Plain Answers About Chimney Problems
- Pellet Stove Ash Disposal and CleaningWhere pellet ash collects, how to remove it safely, and what the maker says about vacuums and containers.Learn more
- Are Pellet Stoves Safer Than Wood Stoves?How the two stove types differ on fuel, power and ash, and why safe use matters more than the label.Learn more
- Common Pellet Stove Problems and What They MeanError codes, a weak fire, squeals and smoke smell, sorted into what you can check and what needs a technician.Learn more
- Can Pellet Stoves Direct Vent?What direct venting means for a pellet stove, the through-wall clearances and where the idea stops.Learn more
Proudly American
A family-owned Sarasota company that explains the price before the work begins.
Questions Sarasota Homeowners Ask Us
Why is my pellet stove not lighting?
The common causes in the manual we read are an igniter switch left in the disabled position, ash around the igniter or in the burn pot, packed burn pot holes, an empty hopper and doors or gaskets that do not seal. Turn the stove off, let it cool and check those before trying again. If the igniter never glows or the status light blinks 5 after cleaning, the igniter or a control needs a technician.
How to light a pilot light on stove?
The Harman manual we read describes an electric igniter for a pellet stove, not a pilot light, and hand lighting with pellet firestarter only as an emergency step. A gas stove or gas fireplace does have a pilot, and its manual describes how to light it, so follow that and never light a pilot by guesswork. If the pilot will not stay lit, call a technician.
Why is my pellet stove not working?
Check the power first, because the auger, igniter and blowers run on household current. Then look at the status light, the hopper, the burn pot and the door seals. The Harman manual says its troubleshooting guide is for a qualified service technician, so stop once the simple checks are done and have the stove looked at.
Book Within 72 Hours of Your Free Inspection and Save 10%
Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.
From Your First Call to the Finished Repair
-
Free inspection
We look at how the stove runs, the pot, the vent and any error light.
-
Written estimate
The cleaning and any repair are written down before work begins.
-
Clean and test
Burn pot, exchanger and vent are cleaned, and the igniter, auger and fans tested.
-
Test burn
We run the stove and confirm it holds a steady flame.
Ready When Your Chimney Is
Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.