Pellet Stove Cleaning, Service and Repair in Sarasota

Burn pot, heat exchanger and vent cleaning, plus checks of the igniter, auger and combustion fan, done from your stove's manual.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Same-day service available, call now

(941) 337-7473 Book a Free Inspection
  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

What pellet stove service and repair includes

Pellet stove service in Sarasota, Venice and Bradenton comes from Sarasota Chimney Repair, a locally owned, family-owned company with an experienced crew, proudly American. A visit is cleaning plus a working check, and repair follows when something has worn out. The same job is also called pellet stove maintenance.

The stove's manual is our guide for what to clean, in what order, and which parts are replaceable. We do not sell stoves or claim any relationship with a maker.

Why a pellet stove stops lighting

A stove that will not start can be a clogged burn pot, a worn igniter, an empty or jammed auger, a closed or blocked vent, a dirty sensor or a control board that reads a fault. We find which one by looking, not by swapping parts.

Ash and clinker can cause a poor burn. Clinker is hard fused ash that blocks air holes in the pot. Cleaning it, and checking that the air path behind it is open, often solves a stove that stalls.

The heat exchanger and exhaust path

Fly ash settles on the heat exchanger and in the passages behind the burn pot. A coated exchanger moves less heat into the room and a coated exhaust path restricts the draft. We open the stove as the manual directs, clean those passages and clear the exhaust fan housing.

Then we check the door gasket, because a worn seal lets room air bypass the burn and changes how the stove runs.

Igniter, auger and combustion fan

The igniter lights the pellets at start-up, the auger feeds them, and the combustion fan pulls air through. When one of the three wears out, the stove shows it with a failed start, a starved flame or a loud fan. We test each, confirm the fault and replace the failed part with one made for your model.

If a model is old and its part is no longer made, we say so before promising a fix. We never fit a part we cannot match to the stove.

The vent pipe to the termination

Exhaust leaves the stove through a pellet vent and ends at a cap outside. We clean the pipe along its run and the termination, and check the joints and the wall or roof pass-through for loose seams or soot streaks. A leaking vent joint can let exhaust gases into the house, which is a carbon monoxide risk, so a loose joint gets fixed before the stove is used again.

The NFPA 211 rule cited by the Chimney Safety Institute says chimneys, fireplaces and vents should be inspected at least once a year. A stove vent belongs in that yearly look.

What you can safely do and what to leave

Between visits you can empty the ash pan and clean the burn pot as your manual says, only when the stove is off and cold. Do not open the stove while it is hot, do not bypass a safety switch, and do not run it with a smoke smell or a visible flame outside the pot. If it will not hold a flame or you smell exhaust, switch it off, ventilate and call us.

What a visit looks like

We start by watching the stove light and run, because a stove that is not running cannot show its fault. Then we turn it off, let it cool, and clean from the burn pot back through the exchanger and the exhaust path. We check the door seal, the igniter, the auger motor and the fans, and we run it again to confirm.

Parts we replace are matched to your model, and you see what was worn. We also point out any part that looks close to failing, so the next stall is not a surprise.

Booking service

Phone us or send the short form. We schedule a free on-site inspection of the stove and give you a written estimate before work starts. Book within 72 hours of the inspection and 10% comes off the service. Installing a new or moved stove is covered at pellet stove installation.

Signs This Work Is Due

Stalls, a smoke smell and sudden shutdowns on a pellet stove usually trace to one of a few dirty, jammed or worn places. Our locally owned, family-owned crew cleans the burn pot, heat exchanger and vent to the outside, and checks the igniter, auger and fan against your manual. We service stoves; we do not sell them.

  • A stove that will not light or that shuts off after a short burn
  • A burn pot that fills with clinker, or a flame that is lazy and smoky
  • The auger that jams, grinds or leaves the pot empty
  • Smoke smell, soot at the vent or an error light on the control board

What the Visit Covers

  1. Cleaning of burn pot, ash pan and heat exchanger
  2. Check of igniter, auger, fans and door seal
  3. Cleaning of the vent pipe to its termination
  4. Replacement of a worn part matched to the stove model

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Do you service a pellet stove you did not install?

Yes. We service pellet stoves we did not install, and we do not sell stoves. We find your model and its manual, clean the stove from the burn pot back through the exhaust path, and test the igniter, auger and fans before we quote any repair.

What is clinker in a pellet stove?

Clinker is hard, fused ash that builds in the burn pot and blocks air holes. It gives a lazy flame and can stall the stove. We remove it and check that the air path behind the pot is open so the stove can breathe again.

Can a pellet stove igniter be replaced?

Yes. We test it first, then fit an igniter made for your stove model. If the stove still fails to start, the fault may be in the auger, the fan or the control board, and we test those parts next before suggesting anything else.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

Urgent Chimney Concern?

Arrange service after immediate hazards have been addressed.

For fire, suspected gas or a carbon monoxide alarm, leave and call 911 from outside.

Call (941) 337-7473

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Chimney & Fireplace Brands We Work With

Call (941) 337-7473