Quick answer
To start a gas fireplace manually, first confirm the maker allows hand lighting. A manual pilot or match-light set can be lit with a long match, but an automatic pilot system must never be lit by hand. Read your manual first. The steps below come from several maker manuals.
First decide whether hand lighting is allowed
The sentence "light a gas fireplace manually" covers three different situations, and for one of them the manual says no. Real Fyre's 02-series instructions state that the appliance has an ignition device that lights the pilot automatically, that you should not attempt to light the pilot by hand and that the valve will not operate if the pilot is not lit and stable.
By contrast, the Real Fyre manual pilot series is built to be lit by hand with a long fireplace match or lighter, and the vent-free insert manual describes a manual lighting procedure for when its ignitor fails. Look at the valve and the manual before you reach for a match.
Starting a manual pilot by hand
This is the sequence in the Real Fyre manual pilot series, which matches the safety pilot kit manual for its APK system.
- Smell for gas around the unit and near the floor. If you smell it, stop.
- Push in the knob slightly and turn it to OFF, then wait five minutes.
- Turn it to PILOT, push it firmly in and hold a long match or lighter at the pilot.
- Keep holding the knob in for about 60 seconds after the pilot lights, then release.
- Turn the knob to ON for the burner, or switch on the toggle switch of an APK system.
- If the pilot does not stay lit, turn the knob to OFF, wait five minutes and repeat. After several tries, call a technician.
Starting a vent-free heater whose ignitor has failed
The vent-free insert manual allows manual lighting as a stopgap. Remove the screen by lifting and pulling it forward, follow the first lighting steps through the PILOT position, strike a match and hold it near the pilot while pressing in the control knob, and keep the knob in for 30 seconds once the pilot lights. The screen goes back on before the heater runs.
The manual says this is to be used until repairs are made, and says to contact a service technician or gas supplier if the pilot will not stay lit.
Starting a gas fireplace with a wall switch or remote
- Gas logs
- Burner
- Ember bed
- Pilot
- Flame sensor
- Gas valve
A wall switch, rocker switch or remote works in one of two ways. On the Real Fyre APK system the pilot is lit by hand and the toggle switch then opens the burner. On a self-lighting system such as the Superior unit, a safety shutoff switch turns on an igniter that sparks, and the main burner ignites once flame appears at the pilot, with no match involved. If the fireplace does not respond, check the batteries in the remote or receiver, any power switch and the equipment shutoff valve, as in our guide on how to fix a gas fireplace that wont light.
The Superior manual also describes a battery back-up for power loss, so a unit that shows no response in an outage may be waiting on its batteries.
Match-light logs and the key
A log set with a key valve and no pilot is lit by laying a burning match on the embers and slowly turning the valve, which the Real Fyre and a vented-log manual both describe. That sequence has its own page, how to light gas fireplace with key.
Safety rules for every manual start
Use your hand only on the knob and never tools, and never force a knob that will not move. Keep the damper open on vented logs and any glass doors open as the maker says. Do not light a pilot if you smell gas, and never use a flame to check for a leak, which the Superior manual says in so many words. If you smell gas, open a window, avoid switches and phones in the house, call your gas supplier from outside and the fire department if you cannot reach them.
The US Fire Administration advises carbon monoxide alarms outside each sleeping area and on every level, so a fireplace you are struggling to light has an alarm nearby when it finally does.
When manual starting is a sign of a repair
If you need a match every time, the ignition or the safety control has failed. Our gas fireplace repair visit finds the cause, whether a dead battery pack, a worn igniter, a thermocouple or the valve itself. Local and family owned, with an experienced crew, we are Proudly American.
A free inspection gets you a written estimate.
Sources
- Florida Building Code, Residential, 2023, chapter 24 Fuel Gas: Appliances installed per manufacturer instructions (G2408.1)
- US Fire Administration, carbon monoxide: Carbon monoxide alarms outside each sleeping area and on every level
- EPA, what is carbon monoxide: Carbon monoxide symptoms
- Real Fyre G45 vented gas log burner installation and owner's manual (R.H. Peterson): 02 series must not be lit by hand; manual pilot series lit with a long match
- Real Fyre automatic remote lighting safety pilot system owner's manual APK-11 (R.H. Peterson): Safety valve pilot lighting; toggle switch operation
- Vent-free gas fireplace insert FDI32R-A owner's operation and installation manual: Manual lighting procedure; safety interlock
- Superior DRT4036 and DRT4042 direct vent gas fireplace installation and operation instructions: Safety shutoff switch and igniter sequence; battery back-up; never use an open flame to check for leaks
- Vented natural gas logs owner's manual, models VL-WO18D to VL-NO30D, match light units with keyed shutoff valve: Match-light key valve sequence
- Family owned and operated
- Licensed & insured
- Same-day service is available
- Locally run
Plain Answers About Chimney Problems
- What Does a Gas Fireplace Thermopile Look Like?A thermopile is easy to confuse with the thermocouple beside it. Here is how the two differ.Learn more
- What to Know About Gas Fireplaces Before You Light OneThe types, the parts, the upkeep and the warning signs, in the order a homeowner needs them.Learn more
- How to Light a Ventless FireplaceThe lighting sequence for a vent-free gas fireplace, what its oxygen sensor does and the room limits that apply.Learn more
- Do Gas Fireplaces Need Regular Maintenance?What maker manuals ask for each year, which checks are yours to do and which belong to a technician.Learn more
Proudly American
A family-owned Sarasota company that explains the price before the work begins.
Questions Sarasota Homeowners Ask Us
How do I start a gas fireplace?
Check which kind of control you have first. A self-lighting system starts from a switch or remote, a hand-lit pilot uses a long match with the knob held in about 60 seconds, and match-light logs use a key valve. Check for gas smell before any attempt.
How do I light a gas fireplace manually?
Only if the maker allows it. For a manual pilot, turn the knob to OFF, wait five minutes, then to PILOT, press it in and hold a long match at the pilot. An automatic 02-series system must not be hand-lit. If it will not stay lit after several tries, call a technician.
How do I start a gas fireplace with a wall switch?
It depends on the system. On a self-lighting unit, turn on the safety shutoff switch, confirm the equipment shutoff valve is open and flip the wall switch; the igniter sparks and the burner lights. On a hand-lit pilot system, light the pilot first, then the switch opens the burner.
Book Within 72 Hours of Your Free Inspection and Save 10%
Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.
From Your First Call to the Finished Repair
-
Describe the change
Tell us where water, soot or damage appeared and when you first noticed it.
-
Review the condition
We look at the relevant system and separate the symptom from the component requiring attention.
-
Agree on the work
Choose the proposed service after the materials, access and price have been explained.
-
Understand the result
We review the completed work and any operating or maintenance questions that remain.
Ready When Your Chimney Is
Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.