Skip to content

Proudly American · Family-Owned & Operated

Call (941) 337-7473

Call (941) 337-7473 Book a Free Inspection

Family owned and operated

Is There a Special Mortar for Fireplaces?

Firebox, smoke chamber and flue liner each call for a different mortar, and the codes name them.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Yes, a fireplace has special mortar where the fire is. The Brick Industry Association prefers firebrick laid in fireclay mortar with thin joints for the firebox, and also accepts Grade SW brick in Type N or Type O portland cement-lime mortar. The Florida Building Code asks for refractory mortar on the flue liner and the smoke chamber.

Which mortar goes in which part of the fireplace

ABCDE
  1. Flue liner
  2. Brick stack
  3. Smoke chamber
  4. Damper
  5. Firebox
The parts this page names, on a simplified drawing of a masonry chimney and fireplace cut through the middle. Highlighted: the brick stack.

A fireplace is built from several zones with very different temperatures, and the masonry rules treat them separately. The Brick Industry Association's Technical Note 19A and the Florida Building Code, chapter 10, name a mortar for each hot zone.

The Florida Building Code asks that clay flue liners are laid in medium-duty, water-insoluble refractory mortar that meets ASTM C199, with tight joints left smooth on the inside. It asks for the inside surface of the smoke chamber to be parged smooth with refractory mortar to the same standard (R1003.12 and R1001.8).

  • Firebox lining: firebrick laid in fireclay mortar to ASTM C 105, which Technical Note 19A calls the preferable construction.
  • Firebox, alternate construction: Grade SW brick laid in Type N or Type O portland cement-lime mortar to ASTM C 270 is also acceptable to the Brick Industry Association, with joints no more than 1/2 inch.
  • Flue liner: refractory mortar to ASTM C199 in tight joints, per the Florida Building Code.
  • Smoke chamber: parged smooth with the same refractory mortar.
  • Damper: seated on a thin bed of the same mortar used in the firebox and not embedded in it.

Why firebox mortar is a thin joint

Technical Note 19A says fireclay mortar joints in the combustion chamber should be 1/16 to 3/16 inch thick, to reduce thermal movement and mortar joint deterioration. It describes a pick-and-dip method, dipping each firebrick in a soupy fireclay mix and setting it straight into place. The Florida Building Code also caps the joints between firebricks at 1/4 inch.

A thick, wide joint is simply a bigger gap for heat and flame to work on. The note also calls for a minimum 1 inch airspace between the firebrick and the brickwork around it, so the lining can expand without pushing on the outer wall.

Cure time before the first fire

New firebox masonry needs time. Technical Note 19A says no fires should be built in the combustion chamber for 30 days after construction, since an early fire drives off the moisture the mortar needs to cure. The same rule holds after a firebox rebuild, so ask for the cure time on the written estimate.

Checking firebox joints you can see

Open joints in the back and sides of the firebox are worth measuring. A ruler held against a gap tells you whether it is wider than the 1/4 inch code limit between firebricks. Loose, crumbling or missing mortar between firebricks, a broken brick or a gap that shows daylight or dark space behind the lining are reasons to stop using the fireplace until someone looks.

Whatever repairs a firebox joint should be a refractory product intended for that spot. A patching compound meant for a patio or a chimney top is not the same material as fireclay mortar. For mortar on the outside of the chimney, see our chimney repair mortar guide.

Factory-built fireplaces work differently

A prefab fireplace has no hand-laid firebrick. Superior's manual for its outdoor factory-built wood burning fireplace describes refractory panels that are installed as pieces inside the steel firebox, and says the fireplace complies with the UL 127 standard for factory-built fireplaces. Its warning is that altering the fireplace or its components may void the listing and create an unsafe installation.

Under the Florida Building Code, factory-built fireplaces must be listed and labeled and installed to the conditions of the listing (R1004.1). A cracked panel is a question for the maker's manual, not for a trowel.

Next step for a Sarasota fireplace

Our crew is local, our company is family owned and run, and the work is Proudly American. An experienced crew rebuilds fireboxes in Sarasota, Venice and Bradenton, and a cracked or open joint becomes a question for fireplace installation work when the lining has to come out. The first step is a free inspection with a written estimate.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Can I use regular mortar in a fireplace firebox?

Technical Note 19A calls firebrick laid in fireclay mortar the preferable construction. It does accept Grade SW brick with Type N or Type O portland cement-lime mortar, with joints no more than 1/2 inch. Refractory mortar is what the Florida Building Code names for flue liners and the smoke chamber, so a hardware-store mix is the wrong choice there.

Do you need special glass for a fireplace?

The Florida Building Code regulates fireplace accessories: they must be listed and labeled (R1001.13). On a factory-built fireplace a gasketed door is allowed only where the fireplace system was tested and listed for one (R1004.5).

How long should new fireplace mortar cure before a fire?

Technical Note 19A says no fires in the combustion chamber for 30 days after construction. A fire sooner than that drives off the moisture the mortar needs. The wait applies to a newly built or rebuilt firebox, not to a routine cleaning.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Describe the change

    Tell us where water, soot or damage appeared and when you first noticed it.

  2. Review the condition

    We look at the relevant system and separate the symptom from the component requiring attention.

  3. Agree on the work

    Choose the proposed service after the materials, access and price have been explained.

  4. Understand the result

    We review the completed work and any operating or maintenance questions that remain.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473