Why Is My Gas Fireplace Pilot Light So Loud?
No maker manual lists a loud pilot by name, so here is what the nearest entries say.
- Licensed & insured
- Same-day service is available
- Locally run
Book Your Free Inspection
Takes about 30 seconds
Request received
Your appointment will be confirmed separately.
Quicker by phone? Call (941) 337-7473
Quick answer
Loud pilot lights on gas fireplaces point to dirt, trapped air or gas pressure, according to the nearest entries in maker manuals. No manual we read lists a loud pilot by name. Hissing and whistling entries blame a dirty orifice, air in the gas line or blocked air passages. Turn the unit off if the flame is yellow.
What the manuals say, and what they do not
We read the troubleshooting tables of the maker documents listed at the end of this page, and none lists a loud pilot as a symptom. Writing a cause for it anyway would be guessing. The honest route is to use the entries that do exist, which are the whistling or hissing entries for a lit burner and the entries for a dirty or badly aimed pilot. A pilot assembly has a small orifice, a hood and an air inlet, so it can suffer from the same trouble as the burner.
- Whistle when the burner is lit: a maker manual lists the control knob turned to high on a cold burner, air in the gas line, blocked air passageways on the heater, or a dirty or partly clogged orifice.
- A yellow tip on the pilot flame: Superior says it can mean dust and dirt in the pilot assembly, which has a small pilot air inlet hole that can be blown clear with the unit off.
- A yellow, luminous or wrong-shaped pilot flame: Enviro's guide says the pilot flame should engulf the thermopile and should not be a yellow luminous flame, and tells the technician to adjust the pilot and check for a clogged pilot injector or a blocked air inlet.
- A pilot that is too short: Desa says a short pilot may stay lit but not create enough heat for the burner to ignite.
- Gas pressure that is off: Superior's service hints list low pressure as a cause of a pilot that will not stay lit and delayed ignition.
When the pilot has changed from how it used to sound
The useful question is what changed. A pilot that was quiet last season and is loud now has picked up dirt, air or a pressure change. A unit that came loud from the start is a different case, and the maker or installer should be asked. In either case, with the unit off and cool, look at the pilot assembly for dust, and with it on, watch the color, size and where the flame touches. A tall pilot, a yellow one or a flame that does not reach the sensor is a reason to turn the unit off.
The pilot will not light
Superior and the other manuals give the same short list for a pilot that will not light. Gas is not reaching the unit, so check the several shutoffs a unit can have. The control knob is not fully pressed in or not held long enough. On a unit with a push-button igniter or electronic spark, wires may be loose, the electrode may be damaged or out of gap, and batteries may be dead. There may be air in the gas line after a refill or service, which a technician purges. On propane, the tank may be nearly empty.
If it will not light after several tries, turn the knob to off and call a technician or the gas supplier, as the manual says.
The pilot is lit but the fireplace will not light
- Burner
- Pilot assembly
- Flame sensor
- Gas valve
- Gas supply line
The Desa guide separates this from the first case, and the answer is a different part. If the pilot lights and stays on after the knob is released, the problem is probably the thermopile side. The thermopile may not be making enough millivolts for the control circuit, or a connection to the switch, thermostat or remote may be loose. The guide describes jumping two valve terminals to test this, which is a job for a technician. The vent-free manual's version of the same fault says the main burner does not light after the pilot is lit when the burner orifice is clogged or inlet gas pressure is too low.
The pilot goes out
A pilot that lights and then goes out when you release the knob, or later, is the thermocouple side. The causes the manuals list are a knob not held long enough, a loose thermocouple connection, a pilot flame that does not touch the thermocouple because of low gas pressure or a dirty pilot, and a safety interlock that has not reset. One manual says to wait one minute for the interlock before another try.
What not to adjust
Pilot flame can be adjusted at a screw on many valves, as the Desa guide notes, but it is adjusted against a millivolt reading. Superior's injector holders are not adjustable and the manual says not to move them. Do not file, bend or clean the pilot assembly with tools. Compressed air at no more than 30 PSI with the unit off and cool for thirty minutes is the method Superior gives for that heater, and a technician should do it when the pilot is the problem.
Florida code and the shutoff valve
The 2023 Florida Building Code, Residential, section G2420.5, requires a shutoff valve for each gas appliance. Normally it is in the same room within 6 feet of the appliance, and for a vented decorative appliance it may be remote if it is accessible and permanently identified. If the noise changes into a roar or the flame goes yellow, close the control and that valve, leave the unit off and call.
A loud pilot or a burner that will not follow it
We are a local, family-owned crew with experienced technicians, and we are Proudly American. If your pilot is loud, will not light, or lights without the burner following, call (941) 337-7473 to book a free on-site inspection and a free written estimate. Our gas fireplace repair page describes how the visit goes.
Sources
- Installation and Operating Manual, model AGVF340 vent-free gas fireplace insert, as hosted by a retailer: Lighting, observed-problem table (noise, delayed ignition, odor, pilot).
- Superior (IHP) Installation and Operation Instructions, Unvented (Vent-Free) Gas Log Heaters, P/N 901336-00 Rev. A: Maker's cleaning, flame, odor and troubleshooting entries for a vent-free gas log heater.
- Desa and IHP gas valve troubleshooting guide (thermocouple, thermopile and ODS valves), as hosted by a parts retailer: How thermocouple and thermopile valves work and where they fail.
- Sherwood Industries (Enviro) Gas Fireplace Service Manual, C-10100, written for trained technicians, as hosted by a parts retailer: Pilot, thermopile, burner and sooting checks.
- 2023 Florida Building Code, Residential, chapter 24 Fuel Gas: Sections G2406.2, G2420.5, G2432, G2434, G2445 quoted on this page.
- Family owned and operated
- Licensed & insured
- Same-day service is available
- Locally run
Plain Answers About Chimney Problems
- Why Does My Propane Fireplace Emit Soot?Soot is the visible sign of a flame that is not burning cleanly.Learn more
- Should a Gas Fireplace Pilot Light Always Stay On?It depends on the ignition system your fireplace was built with.Learn more
- Why Is There a Kerosene Smell Coming From My Gas Fireplace?A chemical smell has a short list of harmless causes, and one cause that is not harmless.Learn more
- Gas Fireplace Sidewall Vent CapWhat the cap on the outside wall does, how to keep it clear and how side, roof and chimney terminations differ.Learn more
Proudly American
A family-owned Sarasota company that explains the price before the work begins.
Questions Sarasota Homeowners Ask Us
Why is my fireplace pilot light so loud?
No maker manual we read lists a loud pilot by name. The nearest entries for hissing and whistling point to a dirty or clogged orifice, air in the gas line, blocked air passages or a turned-up control on a cold burner. A pilot with a yellow tip can mean dust in the pilot assembly. Have a technician look.
How to light a gas fireplace pilot light?
Follow the lighting instructions on your own unit. One vent-free insert label says to turn off the gas, wait five minutes and smell for gas near the floor, then press in the knob, light the pilot, hold the knob for the time given and release it. If the pilot will not stay lit after several tries, stop and call.
Why is my gas fireplace fan so loud?
The blower is a separate part from the pilot and burner. Superior says the circulating air passageways should be kept clean and names lint from carpeting, bedding and pet hair as a reason for more frequent cleaning. A noise that follows the fan switch and not the flame points at the blower.
Book Within 72 Hours of Your Free Inspection and Save 10%
Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.
From Your First Call to the Finished Repair
-
Describe the change
Tell us where water, soot or damage appeared and when you first noticed it.
-
Review the condition
We look at the relevant system and separate the symptom from the component requiring attention.
-
Agree on the work
Choose the proposed service after the materials, access and price have been explained.
-
Understand the result
We review the completed work and any operating or maintenance questions that remain.