Skip to content

Proudly American · Family-Owned & Operated

Call (941) 337-7473

Call (941) 337-7473 Book a Free Inspection

Family owned and operated

Do Pellet Stoves Produce Creosote?

What builds up inside a pellet stove vent, what causes the sooty kind, and how often the manuals say to look.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Yes, a pellet stove can produce creosote and soot, mostly when it burns poorly. The maker manuals link buildup in the vent to a rich, lazy flame and tell owners to inspect the pipe at least once or twice a year. The routine deposit in a pellet vent is fly ash, which restricts the flow and needs cleaning too.

Creosote, soot and fly ash are three different deposits

A pellet stove burns small wood pellets fed by an auger, and the exhaust is pushed out through a sealed pipe by a blower. Three things can collect in that pipe, and they are not the same.

Fly ash is the fine powder that every pellet fire leaves behind. England's Stove Works says it collects in the exhaust venting and restricts the flow of flue gases. Soot is what incomplete combustion leaves, and the same manual names startup, shutdown and incorrect operation as the moments it forms. Creosote is the deposit that the PelPro and Lopi manuals warn about when a stove is running badly.

  • Fly ash: the fine powder every pellet fire leaves, which settles along horizontal runs and at the tee where the pipe turns upward.
  • Soot: left behind when combustion is incomplete, such as at startup, at shutdown or when the stove is run wrongly.
  • Creosote: the deposit the manuals tie to a poorly burning stove, and the one Lopi says must be removed once it is over one quarter inch.

What makes a pellet stove burn poorly

ABCDEF
  1. Hopper
  2. Auger
  3. Burn pot
  4. Control board
  5. Ash pan
  6. Exhaust blower
Not drawn to scale. The numbered parts are named below, with the hopper highlighted.

The PelPro manual says soot or creosote may build up in the exhaust when the stove runs under incorrect conditions, such as an extremely rich burn. It describes that flame as lazy and orange with black tips, which it says points to poor combustion of the fuel. The same manual tells you not to keep running a stove whose flame is dark and sooty or whose firepot overfills with pellets.

England's troubleshooting table lists the causes of a lazy fire: a failing exhaust blower, damp pellets, heavy ash buildup and low-quality pellets. A blocked flue appears in its list for an overfire code. Each cause has a plain remedy in the manual, from keeping pellets dry to cleaning the whole unit.

Do pellet stoves produce carbon monoxide?

A pellet stove is a fuel-burning appliance, so carbon monoxide is a real concern when anything goes wrong. England's Stove Works says that burning a fuel other than wood pellets can create an unsafe situation and can generate excess carbon monoxide, and it strongly recommends a carbon monoxide detector. The PelPro and Lopi manuals add that a stove with a dirty or leaking exhaust can spill smoke into the room.

The vent is the thing to protect. PelPro says the exhaust system must be completely airtight, with every joint sealed. England's notes that a leak in the pipe can usually be found by looking for fly-ash deposits on the outside of the pipe. Fly ash outside the pipe means the joint is not smoke-tight.

How often the manuals say to check the vent

The three manuals do not agree on one number, so follow the one that came with your stove. PelPro and Lopi both say to check the exhaust system twice a year at a minimum for soot or creosote. England's says to inspect the venting at least once every year, and it adds a monthly look at the low spots and direction changes in the pipe and at the termination cap.

Lopi gives the one measurement: creosote accumulation over one quarter inch must be removed. The US Fire Administration separately advises having heating equipment and chimneys cleaned and inspected each year by a professional.

What you can safely look at yourself

Switch the stove off and let it cool completely before you do anything. England's and PelPro both tell you to unplug the unit before maintenance, because the off button does not cut all power to the stove. Never put your fingers in the hopper or near the auger.

  • Remove the cover on the clean-out tee, where the pipe turns upward, and shine a flashlight up the vent. Lopi says this is often the dirtiest spot.
  • Look at the termination cap from the ground and check that nothing is clogging it.
  • Look along each pipe joint for fly-ash dust on the outside of the pipe.
  • Check that the flame, once the stove is running again, is bright and not lazy and orange with black tips.

When to stop and call

Stop using the stove and call if the flame stays dark and sooty after a cleaning, if the firepot keeps overfilling, if you find a crust of creosote thicker than one quarter inch, or if fly ash shows at the pipe joints. Stop at once, open a window and leave the room if a carbon monoxide alarm sounds or smoke is coming into the room.

A cleaned burn pot does not fix a worn exhaust blower or a leaking joint. Those need a technician who can open the stove and the vent.

What a service visit covers

A visit walks the exhaust from the stove to the cap. The technician cleans the burn pot, heat exchange area and exhaust blower, brushes the pipe and the tee, checks the cap, and examines every seam. Joints that are taken apart are resealed with the sealant the maker names and then checked for smoke-tightness.

England's notes that pellet fly ash can be corrosive under certain conditions, so worn pipe sections are looked for and replaced. See pellet stove service for what the visit includes.

Book the vent check before the next cold snap

If you have not had the vent looked at this season, or the flame has gone lazy, book the check before the next cold snap. Sarasota Chimney Repair is a locally owned, family owned and operated company with an experienced crew, Proudly American. Ask for a free on-site inspection and a written estimate. For the wider safety picture read are pellet stoves dangerous.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Do catalytic wood stoves produce less creosote?

This page is about pellet stoves, and the manuals opened for it do not cover catalytic wood stoves, so no figure is given. A catalytic stove still needs its flue inspected, and the US Fire Administration advises a professional cleaning and inspection of heating equipment and chimneys each year. The maker's manual for that stove governs how it is run and cleaned.

Why is my pellet stove not working?

With the stove off, cool and unplugged, look at the common causes in your manual: no power, an empty hopper, a hopper lid left open, a dirty burn pot or clogged vent. England's troubleshooting table also points to a bad exhaust blower or a loose sensor connection. If a code returns after you restart, the stove needs a service visit.

Why is my pellet stove rusting?

England's Stove Works says pellet fly ash can be corrosive under certain conditions, and it asks owners to look at the venting pipe for signs of wear when cleaning. A dusty gray deposit on the outside of a pipe joint can mean a leak as well as a rust problem. Surface rust on the stove body is a separate matter, covered in our guide on pellet stove safety.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Free inspection

    We look at how the stove runs, the pot, the vent and any error light.

  2. Written estimate

    The cleaning and any repair are written down before work begins.

  3. Clean and test

    Burn pot, exchanger and vent are cleaned, and the igniter, auger and fans tested.

  4. Test burn

    We run the stove and confirm it holds a steady flame.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473