Family owned and operated
How to Light Real Fyre Gas Logs
Lighting steps for Real Fyre vented gas logs by valve type, and the damper, screen and glass door rules that apply to every set.
- Licensed & insured
- Same-day service is available
- Locally run
Book Your Free Inspection
Takes about 30 seconds
Request received
Your appointment will be confirmed separately.
Quicker by phone? Call (941) 337-7473
Quick answer
Real Fyre gas logs light one of two ways. A manual pilot (A series) is lit by hand with a long match, and an automatic 02-series pilot lights only from its switch or remote and must never be hand-lit. Check which valve you own, then follow that sequence with the damper fully open.
Which Real Fyre valve do you have
The Real Fyre G45 manual covers several control types in one booklet, and each is lit differently. The manual pilot (A) series has a control knob on the side of the unit with OFF, PILOT and ON positions. The 02 series has an ignition device that lights the pilot automatically, with a remote or a switch box. The 11, 15 and 17 series have their own valve instructions.
Look at the burner and the valve, and at the label or the model on the manual. Following the wrong sequence for your valve is a reason these logs do not light.
Before you light: damper, doors and screen
These logs are made to burn with yellow flames in a solid-fuel fireplace with a working flue, so ventilation is essential. The manual says the chimney damper must be fully open whenever the unit burns, and a damper clamp is included to keep a minimum permanent opening and prevent the blade closing fully. If glass doors are used, they must be fully open while the burner is on, and a fireplace screen must be in place.
Smell around the unit and near the floor. If you smell gas, do not light anything, do not touch switches or use phones in the building, open a window and call your gas supplier from a neighbor's phone, or the fire department if you cannot reach them.
Lighting the manual pilot (A series), step by step
The Real Fyre manual allows the pilot on this series to be lit by hand with a long fireplace match or lighter.
- Push in the control knob slightly and turn it clockwise to OFF.
- Wait five minutes for any gas in the unit to clear, and smell for gas.
- Turn the knob counterclockwise to PILOT, push it firmly and fully in, and hold a long match or lighter near the thermocouple.
- Keep the knob held in for about 60 seconds after the pilot lights, then release it.
- With the pilot burning, turn the knob counterclockwise to ON. The burner lights, about five seconds after the valve opens.
- If the burner does not light within five seconds, turn the knob clockwise to PILOT, wait five minutes and try again.
Lighting the automatic 02 series with a remote
On the 02 series the manual says to use only the control system, or the remote if fitted, to light the pilot, and not to attempt to light it by hand. The valve will not operate unless the pilot is lit and stable. Slide the receiver's three-position switch to REMOTE, press the ON button on the transmitter, listen for the receiver's beep and the spark, and the pilot and burner light in roughly five seconds.
If the pilot or burner fails to light, press OFF, wait five minutes and repeat. After several tries, turn everything to OFF and contact a qualified professional service technician. The 02 series uses D batteries in the burner system, a 12 volt battery in the transmitter and AA batteries in the receiver, so dead batteries are the first thing to try.
Why are my Real Fyre gas logs not lighting
- Gas logs
- Burner
- Ember bed
- Pilot
- Flame sensor
- Gas valve
The G45 troubleshooting table gives the common causes in the order a technician checks them: gas pressure too low, a gas supply or manual shutoff valve that is closed, air in the gas line, a blocked pilot hood, a loose igniter wire or electronic spark that does not fire, and dead batteries. If the pilot lights and will not stay, the thermocouple, pilot line or valve are the likely causes. Our guide on how to fix a gas fireplace that wont light walks that order.
Pilot cleaning, orifices and what stays with a technician
People often ask how to clean the pilot orifice. The manual lists debris or dirt on the pilot hood as a cause and says to clean the pilot, but it gives no method for doing so, and the Superior manual warns never to clean a pilot with a wire or needle. Burner ports and orifices are checked with the burner cool and the gas off, by someone who knows the burner.
Gas pressure, the gas line and replacement parts are for a qualified installer. The manual says to use only Peterson Real Fyre parts, media and accessories, and that installation and service must be done by a qualified professional.
Care after the fire
To shut down the burner only, turn the knob to PILOT. To turn the pilot off for a long period, push in slightly and turn to OFF. The logs stay hot for some time, and the manual says to use heat-resistant gloves or let them cool before moving any log. Black soot on the logs means incomplete combustion, and the manual says to reposition the affected log to reduce flame contact and check ventilation.
Having your Real Fyre set looked at
We work on vented gas log sets in Sarasota homes, and we read the maker's manual for your valve before we touch it. Our gas log installation visit covers new sets plus burner and damper checks. Family owned and local, with an experienced crew, we are Proudly American.
A free inspection comes first, followed by a written estimate.
Sources
- Florida Building Code, Residential, 2023, chapter 24 Fuel Gas: Appliances installed per manufacturer instructions (G2408.1)
- US Fire Administration, carbon monoxide: Carbon monoxide alarms; vents kept clear
- EPA, what is carbon monoxide: Carbon monoxide symptoms; blocked flues
- Real Fyre G45 vented gas log burner installation and owner's manual (R.H. Peterson): Valve series; manual pilot (A) sequence; 02-series remote lighting, no hand lighting, batteries; damper fully open and clamp; glass doors open; screen; troubleshooting table; logs hot after use; soot
- Real Fyre automatic remote lighting safety pilot system owner's manual APK-11 (R.H. Peterson): Safety valve pilot lighting
- Superior DRT4036 and DRT4042 direct vent gas fireplace installation and operation instructions: Never clean the pilot with a wire or needle
- Family owned and operated
- Licensed & insured
- Same-day service is available
- Locally run
Plain Answers About Chimney Problems
- Putting a Gas Fireplace Insert Into an Existing ChimneyWhat the chimney has to be, and what has to be done to it, before a gas insert is installed in an existing fireplace.Learn more
- Gas Fireplace Insert Buying GuideThe questions that decide which gas insert fits your fireplace, before you pick a model or a finish.Learn more
- Dryer Fire Prevention Tips for Sarasota HomesA short list from the fire agencies that study this, sorted by how often you do each step and what to leave to a professional.Learn more
- A Laundry Room Safety Checklist, Dryer to AlarmsWalk the room once with this list: the machine, the lint, the vent, the outside wall and the detectors.Learn more
Proudly American
A family-owned Sarasota company that explains the price before the work begins.
Questions Sarasota Homeowners Ask Us
Why are my gas logs not lighting?
The Real Fyre table lists low gas pressure, a closed shutoff valve, air in the line, a blocked pilot hood, a loose igniter wire and dead batteries. Confirm the damper is open and run the lighting sequence for your valve exactly. If it still fails after several tries, turn it off and call a technician.
How do I clean the pilot orifice on gas logs?
The manual only says to clean a pilot hood that has debris on it. It does not give a homeowner method, and the Superior manual warns never to use a wire or needle on the pilot. Leave cleaning to a technician with the gas off and the unit cool.
Do Real Fyre gas logs need the damper open?
Yes. The manual requires the chimney damper fully open whenever the burner runs and includes a damper clamp so it cannot close. The logs burn with a yellow flame and need ventilation. If glass doors are fitted, they must be fully open too.
Book Within 72 Hours of Your Free Inspection and Save 10%
Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.
From Your First Call to the Finished Repair
-
Describe the change
Tell us where water, soot or damage appeared and when you first noticed it.
-
Review the condition
We look at the relevant system and separate the symptom from the component requiring attention.
-
Agree on the work
Choose the proposed service after the materials, access and price have been explained.
-
Understand the result
We review the completed work and any operating or maintenance questions that remain.
Ready When Your Chimney Is
Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.