Where to Put a Damper on a Wood Stove

Some stoves carry a damper inside, some take one in the pipe, and some must not have one at all.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Where a damper goes on a wood stove depends on the stove. Some, like the Vermont Castings Encore, have a damper built into the stove with its own handle. Others take a butterfly damper in the pipe to tame excess draft, and some stoves are labeled not approved for a flue damper at all, so the maker's manual decides.

Three places a damper can be

Before you add anything, find out which of these your stove already has.

  • Inside the stove: the Vermont Castings Encore manual describes a damper handle on the left side of the stove that opens and closes a damper directing air flow within the stove.
  • In the stovepipe: the Jotul F 3 CB manual says excessive drafts can be corrected by installing a butterfly damper, and tells the owner to consult a dealer if a draft problem is suspected.
  • In the fireplace behind the stove: where a stove sits in a masonry fireplace, the fireplace damper is a separate part that has to be handled as the stove maker directs.

How the built-in damper works on one stove

The Encore is a good example because its manual gives a plain rule. The damper is open when the handle points to the back of the stove, which lets smoke pass directly into the chimney. It must be open when starting or reviving a fire, and whenever the griddle or the doors are opened.

With the handle pointing forward the damper is closed, and smoke from the fire is directed through the catalytic combustion system before it goes up the chimney. The manual adds that closing the damper takes a firm pull so it snaps into the locked position. On this stove, a damper left closed is one reason for smoke when the door opens.

Stoves that must not have a flue damper

Adding a damper is not always allowed. The label printed on the US Stove Logwood 2469E manual states that this single burn rate wood heater is not approved for use with a flue damper. Its manual also warns never to alter the damper slide or the adjustment range of its air control.

The England's Stove Works pellet stove manual is just as direct. It says not to install a flue pipe damper or any other restrictive device in the exhaust venting system.

When a butterfly damper in the pipe makes sense

The Jotul manual describes two draft problems. Too much draft can overheat the stove and shorten burn times, and a butterfly damper is the fix it names. Too little draft is a different problem. It can spill smoke into the room when the stove is loaded or the door is open, and cause back puffing, a buildup of gases in the firebox.

The US Stove manual describes the same two ends. An uncontrollable burn or excessive temperature indicates excessive draft, while inadequate draft puffs smoke back and leaks it at the connector joints. A damper is named as the fix for the first problem only, and it belongs only on a stove whose maker allows one.

A stove inside a masonry fireplace

The Jotul manual says that when the stove is installed in a masonry fireplace, code requires the fireplace damper plate to be removed or securely fixed in the open position, with a connector pipe running from the stove's flue exit through the damper area into the chimney tile liner. It also calls for a new sheet metal block-off plate around the connector pipe at the damper frame, sealed with proper sealant.

The Vermont Castings manual asks for the fireplace damper to be sealed so room air does not escape up the flue, while remaining possible to reopen for inspection or cleaning. Two stoves, two methods. Follow the one printed in your own manual.

Settings and the signs they are wrong

There is no universal damper setting. The Encore manual says the primary air lever controls the amount of incoming air, that more air makes the fire burn hotter and faster, and that less air prolongs the burn at a lower heat. The US Stove manual advises learning to set the air to produce the smallest visible smoke.

Signs of a wrong setting or a draft problem are smoke at the door when loading, a stovepipe that glows, a fire that cannot be slowed and a chimney that stays cold and wet. The US Stove manual says overfiring can cause a house fire and that a glowing unit or connector means overfiring. Our smoking wood stove guide covers the smoke side.

Florida chimney rules that set the draft

ABCDE
  1. Room air feeding the fire
  2. Fireplace
  3. Smoke and gases rising
  4. Top of the flue
  5. The house
Not drawn to scale. The numbered parts are named below, with the smoke and gases rising highlighted.

Draft depends partly on the chimney. The Florida Building Code requires a masonry chimney to extend at least 2 feet higher than any part of a building within 10 feet, and at least 3 feet above the highest point where it passes through the roof (R1003.9). It also sets rules for flue linings (R1003.11). The US Stove manual gives the same height rule and says a chimney top lower than the roof or a nearby tree lets wind beat the smoke back down.

Next step for a Sarasota wood stove

ABCDEF
  1. Insulated chimney
  2. Roof flashing
  3. Connector pipe
  4. Pipe damper
  5. Baffle
  6. Firebox
Where the firebox sits: a freestanding wood stove and its chimney, drawn simply and not to scale.

A family-owned company with a local crew, Proudly American, installs and services wood stoves in Sarasota, Venice and Bradenton, and an experienced crew sets the connector pipe and air controls to the maker's manual. See wood stove service, then ask for a free inspection with a written estimate.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

Why does my wood stove not have a damper?

Many stoves control the fire with an air supply instead. The US Stove Logwood 2469E label says that single burn rate heater is not approved for use with a flue damper, and the England's Stove Works pellet manual says not to install one in the exhaust. A stove built without a damper should stay that way.

Can you put a tv near a wood stove?

Only at the distance the stove manual allows. The US Fire Administration says to keep anything that can burn at least 3 feet from wood stoves, and a television is made of such material. Valor adds that most television makers rate their screens up to about 100 to 104 degrees Fahrenheit.

Do i need a flue damper on my wood stove?

No manual we read requires one. The Jotul manual names a butterfly damper only as a fix for excessive draft, and consults the dealer first, while the US Stove label forbids one on its stove. If your stove runs too hot, check the chimney height and connector before anything else.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Free inspection

    We look at the room, the stove, the manual and the chimney.

  2. Written estimate

    Scope and cost are written down before work begins.

  3. Install

    Hearth pad, stove, connector pipe and liner or chimney are set to the listing.

  4. First fire

    We light a small fire, check every joint and show you the controls.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473