How to Wire a Fireplace Wall Switch

Gas fireplaces and electric fireplaces use the same switch plate for two very different circuits.

  • Licensed & insured
  • Same-day service is available
  • Locally run

Book Your Free Inspection

Takes about 30 seconds

Quicker by phone? Call (941) 337-7473

Quick answer

Fireplace wall switches are wired one of two ways, and the fireplace type decides which. On a gas fireplace the switch joins a low-voltage control circuit and must never be tied to 120-volt household power. On an electric fireplace it belongs to a household circuit, which is electrician work. The unit's manual names the exact method.

One switch plate, two different circuits

People say wall switch for a gas fireplace and for an electric one, but the wiring behind the plate has little in common. A gas fireplace uses the switch as a remote ON/OFF button for its burner. An electric fireplace draws household power, and the switch may sit directly in that supply.

Mixing the two up is where trouble starts, because the two circuits are not interchangeable. So the first job is to name the appliance, read its model plate and find the maker's manual.

A gas fireplace switch is a low-voltage control

ABC
  1. Burner
  2. Pilot
  3. Gas valve
Simplified drawing, not to scale. The gas valve is marked in colour.

The Lennox Hearth manual for its ADAGIO direct vent fireplaces shows the pattern clearly. On a millivolt model, the maker says an optional wall-mounted switch, a wall thermostat or a remote kit may be used in place of the switch on the unit. The switch is wired into the millivolt control circuit with two-conductor wire, and the manual says 15 feet of that wire is supplied with the unit.

The same page carries a plain caution. The optional wall switch must not be connected to a 120-volt power supply. On the electronic models, the wall control is also wired into the low-voltage circuit, while the appliance itself is connected to the main power supply.

  • Switch on the unit: a rocker switch is built into the control compartment at the factory.
  • Wall switch, thermostat or remote kit: optional controls the maker allows on that model.
  • Control wire: two conductors run to the gas valve circuit, not to household power.
  • Unit's own switch: the manual says to turn it to OFF once an optional control is installed, so the wall control commands the burner.

An electric fireplace switch is part of a household circuit

Dimplex says many of its electric fireplace models plug into a standard 120-volt outlet, while other units need a more involved installation that includes hard-wiring. Its support page advises keeping your skill level in mind and working with a local installer for anything beyond plugging in.

Circuit load matters too. The Dimplex service manuals list a breaker that trips when the unit is turned on, or lights that dim when it runs, as signs the unit is drawing close to the circuit rating. Their remedy is another outlet or a dedicated 15 amp circuit. A new wall switch does not change that load, so the circuit has to be sized for the unit first.

Wiring that should go to a qualified electrician and gas installer

Anything that connects to the 120-volt supply, adds a circuit, opens a wall or touches the gas valve belongs to a qualified electrician or gas installer. A connection the maker does not describe is outside the instructions for the unit.

The Florida Building Code points the same way. Factory-built fireplaces must be installed to the conditions of their listing (R1004.1), and listed fireplace accessories follow the listing and the manufacturer's instructions (R1001.13). A control kit that is not the one the maker lists is outside those conditions.

What a homeowner can check without opening anything

Read the model plate and write the model number down. Find the manual and look up its wiring page or its controls page. Check whether the switch on the unit itself is in the position the manual calls for when a wall control is in use, because a unit switch left in the wrong position can make a good wall switch look dead.

Turn off power at the panel before touching any cover, and never reach into a gas fireplace's control compartment while the pilot is lit. If the unit has a blower, the Lennox manual adds that the main power supply and wall switch have to be installed before the fireplace is framed and enclosed, so a blower added later may need wall work.

When the wall switch seems to have stopped working

A dead switch, a loose low-voltage wire and a fault in the unit's own control give the same symptom, which is nothing. Work from the unit outward. Does the unit's own switch run the fireplace? If it does, the problem sits in the wall switch or its wire.

If the unit does not respond either, treat it as a fireplace problem, not a wiring project. The US Fire Administration advises having heating equipment and its vents cleaned and inspected each year by a professional. Our gas fireplace goes out guide covers the gas side in more detail.

Next step for a Sarasota home

Sarasota Chimney Repair is a locally owned, family-run company, Proudly American, and its experienced crew installs electric fireplaces across Sarasota, Venice and Bradenton. A switch location is easiest to settle before the walls close, so raise it at the start of an electric fireplace installation. Ask for a free inspection and a written estimate, and read our built-in electric fireplace guide to plan the opening.

Sources

  • Family owned and operated
  • Licensed & insured
  • Same-day service is available
  • Locally run

Proudly American

A family-owned Sarasota company that explains the price before the work begins.

Call (941) 337-7473

Questions Sarasota Homeowners Ask Us

How to turn on fireplace with wall switch?

Flip the switch to ON after checking the switch on the unit itself. On a millivolt Lennox Hearth model, the maker says to set the unit's own switch to OFF when a wall switch is installed, so the wall switch alone commands the burner. If nothing happens, the pilot, the low-voltage wires and the gas valve are the next checks, and those are service work.

How to use gas fireplace with wall switch?

Use it exactly as the unit's manual describes. The Lennox Hearth manual lists a wall switch, a wall thermostat and a remote kit as interchangeable optional controls on its ADAGIO models. Each one is wired into the low-voltage circuit, and none of them may be connected to 120-volt household power.

How to wire fireplace?

The method depends on the fireplace. A gas fireplace takes low-voltage control wiring, while an electric fireplace either plugs into a 120-volt outlet or is hard-wired to a household circuit. The Florida Building Code requires factory-built fireplaces to be installed to their listing, so the maker's manual and a qualified electrician decide the details.

Book Within 72 Hours of Your Free Inspection and Save 10%

Any service you book within 72 hours of your free inspection comes with 10% off. The written estimate is free either way.

Book a Free Inspection

From Your First Call to the Finished Repair

  1. Describe the change

    Tell us where water, soot or damage appeared and when you first noticed it.

  2. Review the condition

    We look at the relevant system and separate the symptom from the component requiring attention.

  3. Agree on the work

    Choose the proposed service after the materials, access and price have been explained.

  4. Understand the result

    We review the completed work and any operating or maintenance questions that remain.

Ready When Your Chimney Is

Call our family-run office in Sarasota for a free inspection, or send the short form and we will call back to set a time. We cover Sarasota and Venice in Sarasota County and Bradenton in Manatee County, and nowhere else.

Call (941) 337-7473